A Discussion on Contact Condition in Simulation of RCFT Columns
- DOI
- 10.2991/icmce-14.2014.117How to use a DOI?
- Keywords
- Numerical Simulation, Contact, CFT, RCFT, ADINA
- Abstract
In numerical simulation of Concrete Filled Steel Tubular (CFT) columns the treatments to simulation the contact between steel tube and concrete differed greatly between the researchers, and there is also no any unified standard for the friction between the concrete and steel materials. To examine proper contact condition in simulating Reinforced Concrete Filled Steel Tubular (RCFT) columns with ADINA, numerical simulations are performed employing frictionless, frictional and bonding contact conditions between steel tube and concrete core, the analytical results are compared against experimental results, and the applicability of each contact on RCFT is observed, and a proper contact condition is proposed.
- Copyright
- © 2014, the Authors. Published by Atlantis Press.
- Open Access
- This is an open access article distributed under the CC BY-NC license (http://creativecommons.org/licenses/by-nc/4.0/).
Cite this article
TY - CONF AU - Alifujiang XIAMUXI AU - Akenjiang TUOHUTI AU - Akira HASEGAWA PY - 2014/12 DA - 2014/12 TI - A Discussion on Contact Condition in Simulation of RCFT Columns BT - Proceedings of the 2014 International Conference on Mechanics and Civil Engineering PB - Atlantis Press SP - 673 EP - 678 SN - 2352-5401 UR - https://doi.org/10.2991/icmce-14.2014.117 DO - 10.2991/icmce-14.2014.117 ID - XIAMUXI2014/12 ER -