Determination of bisphenol A in beer by immunoaffinity column tandem high-performance liquid chromatography
- DOI
- 10.2991/icitmi-15.2015.40How to use a DOI?
- Keywords
- bisphenol A; immune-affinity column; high-performance liquid chromatography
- Abstract
A rapid and sensitive method using immuno-affinity columns (IACs) as sample purification procedure and high-performance liquid chromatography (HPLC) tandem fluorescence detector (FLD) for detection has been developed for the determination of bisphenol A (BPA) in beer. The limit of detection (LOD) is 0.28 ng/ml (S/N=3) and the limit of quantity (LOQ) is 0.95 ng/ml (S/N=10). For standard adding and recovery experiments toward beer sample with addition of four-level bisphenol A, the average recovery ratio range from 74.56% to 97.60%, and the relative standard deviations (RSD) range 1.04% to 9.77%. In conclusion, this method is an appropriate way for detection of BPA. For the detection of canned beer samples of various brands, the detection rate is as high as 100%.
- Copyright
- © 2015, the Authors. Published by Atlantis Press.
- Open Access
- This is an open access article distributed under the CC BY-NC license (http://creativecommons.org/licenses/by-nc/4.0/).
Cite this article
TY - CONF AU - K.H. Li AU - L.X. Zhu AU - R.R. Liu AU - W. Meng PY - 2015/10 DA - 2015/10 TI - Determination of bisphenol A in beer by immunoaffinity column tandem high-performance liquid chromatography BT - Proceedings of the 4th International Conference on Information Technology and Management Innovation PB - Atlantis Press SP - 230 EP - 234 SN - 2352-538X UR - https://doi.org/10.2991/icitmi-15.2015.40 DO - 10.2991/icitmi-15.2015.40 ID - Li2015/10 ER -