Experimental study on high strength bolt pre-tightening force of friction energy dissipation device
- DOI
- 10.2991/icismme-15.2015.48How to use a DOI?
- Keywords
- High-strength Bolts; Turn-nut Method; Friction-energy-dissipation Device;
- Abstract
The pre-tightening force experiment to high-strength bolts of friction-energy-dissipation device were implemented by the turn-nut method and then obtained the linear scale between pre-tightening force and angle of rotation by analyzing the data. This provides a reference for the measurement of bolt pre-tightening force. At the same time computed the stiffness of connection attachments and connected members by Workbench and the pre-tightening force of bolts with related parameters. The comparative results with the experimental data can make a reference for applications of high–strength bolts connection in friction-energy-dissipation devices.
- Copyright
- © 2015, the Authors. Published by Atlantis Press.
- Open Access
- This is an open access article distributed under the CC BY-NC license (http://creativecommons.org/licenses/by-nc/4.0/).
Cite this article
TY - CONF AU - Xiao Mei AU - Guo Chen AU - Hai-yang Liu PY - 2015/07 DA - 2015/07 TI - Experimental study on high strength bolt pre-tightening force of friction energy dissipation device BT - Proceedings of the First International Conference on Information Sciences, Machinery, Materials and Energy PB - Atlantis Press SP - 245 EP - 249 SN - 1951-6851 UR - https://doi.org/10.2991/icismme-15.2015.48 DO - 10.2991/icismme-15.2015.48 ID - Mei2015/07 ER -