Comparative Study of Long Span Beams Built up with an Ordinary Structural Steel at High Temperatures
Authors
In-Kyu Kwon
Corresponding Author
In-Kyu Kwon
Available Online April 2016.
- DOI
- 10.2991/icemie-16.2016.51How to use a DOI?
- Keywords
- component; ordinary structural steel; fire resistance; long span beam; structural stability
- Abstract
Fire resistance for steel framed buildings is very important not only to guard lives that live and visit but to sustain the structural stability to prevent falling down. To evaluate and compare the fire resistance of long span beams built with ordinary structural steels, fire engineering method using mechanical properties at high temperatures and a heat transfer theory and a stress analysis was applied. Long span beams made of SS 400, SM 400 showed similar results in aspects of maximum load capacities and deflections during high temperatures.
- Copyright
- © 2016, the Authors. Published by Atlantis Press.
- Open Access
- This is an open access article distributed under the CC BY-NC license (http://creativecommons.org/licenses/by-nc/4.0/).
Cite this article
TY - CONF AU - In-Kyu Kwon PY - 2016/04 DA - 2016/04 TI - Comparative Study of Long Span Beams Built up with an Ordinary Structural Steel at High Temperatures BT - Proceedings of the 2016 International Conference on Electrical, Mechanical and Industrial Engineering PB - Atlantis Press SP - 204 EP - 207 SN - 2352-5401 UR - https://doi.org/10.2991/icemie-16.2016.51 DO - 10.2991/icemie-16.2016.51 ID - Kwon2016/04 ER -