Effect of concentration difference of chloride ions on the corrosion of steel bar
- DOI
- 10.2991/iceesd-18.2018.160How to use a DOI?
- Keywords
- Reinforced concrete, Macro cell corrosion, Chlorine ion concentration difference, Area ratio of cathode and anode
- Abstract
Corroded area rate, weight loss rate and the macro cell corrosion of rebars in concrete subjected to concentration difference of chloride ion was investigated. In order to evaluate the corrosion mechanism of rebars, the corrosion behaviour of rebars in concrete under different chloride concentration difference were contrasted with that of the concrete contaminated with uniform chlorine ion concentration. Results indicated that compared with the concrete contaminated with uniform chlorine ion concentration, the rebars corroded area are higher in concrete under different chloride ion concentration difference, and the rebars corroded area are also higher in concrete in large cathode small anode contrasted with that of the condition in large cathode small anode. Furthermore, the both of rebars corroded area is more serious than uniform chlorine ion concentration.
- Copyright
- © 2018, the Authors. Published by Atlantis Press.
- Open Access
- This is an open access article distributed under the CC BY-NC license (http://creativecommons.org/licenses/by-nc/4.0/).
Cite this article
TY - CONF AU - Haibin Shu AU - Yilin Song AU - Junzhe Liu PY - 2018/05 DA - 2018/05 TI - Effect of concentration difference of chloride ions on the corrosion of steel bar BT - Proceedings of the 2018 7th International Conference on Energy, Environment and Sustainable Development (ICEESD 2018) PB - Atlantis Press SP - 884 EP - 887 SN - 2352-5401 UR - https://doi.org/10.2991/iceesd-18.2018.160 DO - 10.2991/iceesd-18.2018.160 ID - Shu2018/05 ER -