Experimental studies of reinforced concrete shear walls retrofitted with slotted steel plates
- DOI
- 10.2991/iceep-17.2017.211How to use a DOI?
- Keywords
- strengthening;shear wall;slotted steel plate;collapse performance
- Abstract
Many concrete shear walls are always subjected to high gravitational loads and prone to brittle shear failure under the lateral seismic loading which probably leads to the collapse of the whole shear walls system. This paper aims to present a new method of using slit steel plates to retrofit reinforced concrete shear walls, and emphatically analyze the anti-collapse and anti-seismic performance of the retrofitted specimens. A total of 4 shear wall specimens are conducted under lateral cyclic loading tests. One is the original specimen and the others are reinforced with slotted steel plates. The experimental results show that the specimens with slotted steel pate can achieve better anti-collapse performances than that without opening of steel plate.
- Copyright
- © 2017, the Authors. Published by Atlantis Press.
- Open Access
- This is an open access article distributed under the CC BY-NC license (http://creativecommons.org/licenses/by-nc/4.0/).
Cite this article
TY - CONF AU - B. Cheng AU - X.J. Gao AU - M.J. Zhou AU - Q. Zhang PY - 2017/06 DA - 2017/06 TI - Experimental studies of reinforced concrete shear walls retrofitted with slotted steel plates BT - Proceedings of the 2017 6th International Conference on Energy and Environmental Protection (ICEEP 2017) PB - Atlantis Press SP - 1205 EP - 1208 SN - 2352-5401 UR - https://doi.org/10.2991/iceep-17.2017.211 DO - 10.2991/iceep-17.2017.211 ID - Cheng2017/06 ER -