Time-frequency analysis in pick cutting coal seam with small fault
- DOI
- 10.2991/iceeecs-16.2016.212How to use a DOI?
- Keywords
- shearer drum; small fault; cutting experiments; time-domain analysis; frequency-domain analysis
- Abstract
Based on the study of cutting theory of shearer pick-shaped cutter used in thin seams, cutting tests under different fault conditions were done by using pick on the Cutting Test Bed of the Coal and Rock. The results show that: picking Cutting Torque in the coal seam and small fault interface increases with the increase compressive strength difference between the coal seam and small fault. Meanwhile, the mean increments of the cutting torque did not change exponentially, when the thickness of full fault is twice the thickness of top fault or bottom fault in the cutting tests. Through time-domain analysis and frequency-domain analysis of cutting load, it can be seen that probability density curves of pick torque obeys normal distribution in cutting coal seams and small fault. The drum speed affects load fluctuations a lot different forms of coal and rock has some impact on the load fluctuation.
- Copyright
- © 2016, the Authors. Published by Atlantis Press.
- Open Access
- This is an open access article distributed under the CC BY-NC license (http://creativecommons.org/licenses/by-nc/4.0/).
Cite this article
TY - CONF AU - Chenxu Luo AU - Shuangxi Jing AU - Xiaoyu Yang AU - Jinle Yuan AU - Changlong Du PY - 2016/12 DA - 2016/12 TI - Time-frequency analysis in pick cutting coal seam with small fault BT - Proceedings of the 2016 4th International Conference on Electrical & Electronics Engineering and Computer Science (ICEEECS 2016) PB - Atlantis Press SP - 1106 EP - 1110 SN - 2352-538X UR - https://doi.org/10.2991/iceeecs-16.2016.212 DO - 10.2991/iceeecs-16.2016.212 ID - Luo2016/12 ER -