Research on the Detection Technology of Defects in the Bottom Joint of the Precast Shear Wall Based on Ultrasonic Imaging Method
- DOI
- 10.2991/iccte-17.2017.111How to use a DOI?
- Keywords
- ultrasonic imaging method, bottom joint of the precast shear wall, defect
- Abstract
The ultrasonic imaging method takes advantage of the technique of multichannel pulse echo, continuous plane monitoring scanning can be achieved in a single region, and no couplant is required. The experimental investigations on using the ultrasonic imaging method to detect the defects in the bottom joint of the precast shear wall are conducted. Results indicate: this method can effectively locate the position of defects in the bottom joint; to judge the defects more accurately, the ultrasonic imaging method can be combined with the widely used ultrasonic method. In future, the research on the application of the ultrasonic imaging method in practical engineering will conducted.
- Copyright
- © 2017, the Authors. Published by Atlantis Press.
- Open Access
- This is an open access article distributed under the CC BY-NC license (http://creativecommons.org/licenses/by-nc/4.0/).
Cite this article
TY - CONF AU - Rundong Gao AU - Xiangmin Li AU - Fuwen Zhang AU - Hui Liu AU - Yubing Leng PY - 2017/07 DA - 2017/07 TI - Research on the Detection Technology of Defects in the Bottom Joint of the Precast Shear Wall Based on Ultrasonic Imaging Method BT - Proceedings of the 2017 2nd International Conference on Civil, Transportation and Environmental Engineering (ICCTE 2017) PB - Atlantis Press SP - 636 EP - 641 SN - 2352-5401 UR - https://doi.org/10.2991/iccte-17.2017.111 DO - 10.2991/iccte-17.2017.111 ID - Gao2017/07 ER -