Research of Shielding Effectiveness of Metallic Experiment Box Based on Modal Method of Moments
- DOI
- 10.2991/iccsee.2013.6How to use a DOI?
- Keywords
- Rectangular enclosure, Apertures, SE, MoM, Green’s function
- Abstract
In this paper, electric field shielding effectiveness (SE) of metallic experiment box with apertures illuminated by vertical polarization plane wave has been studied by using modal method of moment technique. Electric field SE has been calculated at three different points on the same plane inside enclosure. The numerical results of the proposed technique are in very good agreement with data available in the literature and experimental results. It is shown that apertures’ position, aperture’ number and calculation points have noticeable effect on the electric field SE, four apertures is a better select to improve the shielding ability of an enclosure than one aperture while they have the same area.
- Copyright
- © 2013, the Authors. Published by Atlantis Press.
- Open Access
- This is an open access article distributed under the CC BY-NC license (http://creativecommons.org/licenses/by-nc/4.0/).
Cite this article
TY - CONF AU - Guishu Xia AU - Chao Zhou PY - 2013/03 DA - 2013/03 TI - Research of Shielding Effectiveness of Metallic Experiment Box Based on Modal Method of Moments BT - Proceedings of the 2nd International Conference on Computer Science and Electronics Engineering (ICCSEE 2013) PB - Atlantis Press SP - 20 EP - 24 SN - 1951-6851 UR - https://doi.org/10.2991/iccsee.2013.6 DO - 10.2991/iccsee.2013.6 ID - Xia2013/03 ER -