One key issue of seafloor observatory network is to ensure that the whole system operates normally when some equipment failure exists. Branch Unit can cut off the connection between the failure parts and the backbone network automatically and protect other equipment of the network from the impact of equipment failure. This paper proposes a design of the Branch Unit. The Branch Unit uses zener diode to provide power for the control circuits and constructs DWDM system with the help of the OADM. One Branch Unit model was built in this paper. Experiments verify the principle and functions of the Branch Unit and prove the feasibility of the design. The design provides a reference for the realization of the seafloor observatory network.
- Copyright
- © 2013, the Authors. Published by Atlantis Press.
- Open Access
- This is an open access article distributed under the CC BY-NC license (http://creativecommons.org/licenses/by-nc/4.0/).
Cite this article
TY - CONF AU - Yingbin Feng AU - Zhigang Li AU - Xiaohui Wang PY - 2014/05 DA - 2014/05 TI - Branch Unit for Seafloor Observatory Network BT - Proceedings of the 2012 2nd International Conference on Computer and Information Application (ICCIA 2012) PB - Atlantis Press SP - 1334 EP - 1337 SN - 1951-6851 UR - https://doi.org/10.2991/iccia.2012.331 DO - 10.2991/iccia.2012.331 ID - Feng2014/05 ER -