Analysis of the Dielectric Loss in the Transmission Line Based on Time Domain BLT Equation
- DOI
- 10.2991/iccia.2012.285How to use a DOI?
- Keywords
- Dielectric Loss,Leak Conductance,Coaxial Cable,BLT Equation
- Abstract
Dielectric loss is caused due to imperfect dielectric insulation, in order to study the impact of the dielectric loss consider a uniform loss transmission line with leak conductance. The BLT equation from the frequency domain to time domain is derived to improve the time domain BLT equation, and the aim of using the time domain BLT equation to calculate load voltage of the transmission line with transient signal source, through the calculation results to analyze the impact of the dielectric loss. The results showed that the attenuation of the terminal load transient response voltage occurred when the dielectric loss exists, and this effect is nonlinear.
- Copyright
- © 2013, the Authors. Published by Atlantis Press.
- Open Access
- This is an open access article distributed under the CC BY-NC license (http://creativecommons.org/licenses/by-nc/4.0/).
Cite this article
TY - CONF AU - Wanjin Wang AU - Zhiwu Xuan PY - 2014/05 DA - 2014/05 TI - Analysis of the Dielectric Loss in the Transmission Line Based on Time Domain BLT Equation BT - Proceedings of the 2012 2nd International Conference on Computer and Information Application (ICCIA 2012) PB - Atlantis Press SP - 1156 EP - 1159 SN - 1951-6851 UR - https://doi.org/10.2991/iccia.2012.285 DO - 10.2991/iccia.2012.285 ID - Wang2014/05 ER -