Failure Analysis of Welding Insulation Cyliender
- DOI
- 10.2991/iccet-15.2015.320How to use a DOI?
- Keywords
- cylinder; welding; explosion; failure analysis
- Abstract
In order to analyze the failure cause of welding insulation cylinder, to which explosion had happened, in a filling station, a series of experiments and analysis were taken, including macroscopic analysis, chemical composition analysis, fracture Analysis, metallographic examination and so on. The results showed that irrational structure led to fatigue cracking of fillet weld, connecting the inner-shell and neck pipe, and then pure oxygen continuously leaked into the vacuum interlayer. Friction heat or static electricity generating with the leaking finally caused combustion and explosion of flammable insulation materials in the interlayer. At the end, proposals were put forward.
- Copyright
- © 2015, the Authors. Published by Atlantis Press.
- Open Access
- This is an open access article distributed under the CC BY-NC license (http://creativecommons.org/licenses/by-nc/4.0/).
Cite this article
TY - CONF AU - Hua Li AU - Lian Wang AU - Zhongming Lu AU - Kexiu Liu AU - Weijian Qu AU - Jinmei Lin PY - 2015/11 DA - 2015/11 TI - Failure Analysis of Welding Insulation Cyliender BT - Proceedings of the 5th International Conference on Civil Engineering and Transportation 2015 PB - Atlantis Press SP - 1718 EP - 1724 SN - 2352-5401 UR - https://doi.org/10.2991/iccet-15.2015.320 DO - 10.2991/iccet-15.2015.320 ID - Li2015/11 ER -