Pullout Bond Properties of Grout-Filled Mechanical Splice for Precast Concrete Construction
Authors
Yongfeng Zheng, Zhengxing Guo, Xie Ming
Corresponding Author
Yongfeng Zheng
Available Online November 2015.
- DOI
- 10.2991/iccet-15.2015.204How to use a DOI?
- Keywords
- grout-filled pipe splice, bond, precast concrete
- Abstract
A new type of grouting coupler for rebar splicing was fabricated with common seamless steel pipe by cold rolling technique. Seven splice specimens were prepared with the sleeve and tested under pullout load. The test results have shown that given a proper embedded length, the specimens provided good behaviour of which the ultimate tension load exceeded the required loading capacity specified in ACI318 and JGJ107. The pullout behavior of grout-filled pipe splice are influenced by the inner cavity structure of the sleeve.
- Copyright
- © 2015, the Authors. Published by Atlantis Press.
- Open Access
- This is an open access article distributed under the CC BY-NC license (http://creativecommons.org/licenses/by-nc/4.0/).
Cite this article
TY - CONF AU - Yongfeng Zheng AU - Zhengxing Guo AU - Xie Ming PY - 2015/11 DA - 2015/11 TI - Pullout Bond Properties of Grout-Filled Mechanical Splice for Precast Concrete Construction BT - Proceedings of the 5th International Conference on Civil Engineering and Transportation 2015 PB - Atlantis Press SP - 1078 EP - 1081 SN - 2352-5401 UR - https://doi.org/10.2991/iccet-15.2015.204 DO - 10.2991/iccet-15.2015.204 ID - Zheng2015/11 ER -