Proceedings of the International Conference of CELSciTech 2019 - Science and Technology track (ICCELST-ST 2019)

Failure Analysis of Condenser Tube in Unit 1 of the Tenayan Steam Power Plant 2 X 110 MW

Authors
Nur Rohman Aziz, Ahmad Kafrawi Nasution, Ridwan Abdurrahman
Corresponding Author
Ahmad Kafrawi Nasution
Available Online December 2019.
DOI
10.2991/iccelst-st-19.2019.13How to use a DOI?
Keywords
Condenser, Erosion Corrosion, RCFA, turbidity, dent
Abstract

This study conducted a failure analysis of the condenser tube in unit 1 of the Tenayan Steam Power Plant. It started from the inspection in the first year after the commercial off date (COD) where there is a leaky tube, so there is further suspicion. Various tests and analysis are carried out such as tube vacuum testing, Eddy current testing, condenser tube material analysis, condenser water quality analysis, effectiveness and heat transfer on a condenser to the determination of root cause failure analysis to ensure condenser performance. From the results obtained, the cause of the failure of the condenser tube in unit 1 is the thinning of the condenser tube wall. The failure mechanism is erosion corrosion caused by the use of water in condensers that contain high turbidity.

Copyright
© 2019, the Authors. Published by Atlantis Press.
Open Access
This is an open access article distributed under the CC BY-NC license (http://creativecommons.org/licenses/by-nc/4.0/).

Download article (PDF)

Volume Title
Proceedings of the International Conference of CELSciTech 2019 - Science and Technology track (ICCELST-ST 2019)
Series
Advances in Engineering Research
Publication Date
December 2019
ISBN
978-94-6252-852-9
ISSN
2352-5401
DOI
10.2991/iccelst-st-19.2019.13How to use a DOI?
Copyright
© 2019, the Authors. Published by Atlantis Press.
Open Access
This is an open access article distributed under the CC BY-NC license (http://creativecommons.org/licenses/by-nc/4.0/).

Cite this article

TY  - CONF
AU  - Nur Rohman Aziz
AU  - Ahmad Kafrawi Nasution
AU  - Ridwan Abdurrahman
PY  - 2019/12
DA  - 2019/12
TI  - Failure Analysis of Condenser Tube in Unit 1 of the Tenayan Steam Power Plant 2 X 110 MW
BT  - Proceedings of the International Conference of CELSciTech 2019 - Science and Technology track (ICCELST-ST 2019)
PB  - Atlantis Press
SP  - 65
EP  - 69
SN  - 2352-5401
UR  - https://doi.org/10.2991/iccelst-st-19.2019.13
DO  - 10.2991/iccelst-st-19.2019.13
ID  - Aziz2019/12
ER  -