The Buildings Explosion Venting Research For The Gas Resource Utilization
- DOI
- 10.2991/icaees-15.2015.235How to use a DOI?
- Keywords
- Gas explosion, Deflagration venting, Light friable system,Vent area, Detection method
- Abstract
For the advantages such as clean and environmental,the gas has been frequently used in human production and living.However,the gas explosion also becomes the major threaten for the production safety,the casualties caused by which is mainly due to the buildings collapse.This paper studies the deflagration venting of the buildings.First,by combining the research home and abroad,we analyze the impacts of vent area on the explosion pressure. We Compare different countries' specification of explosion venting area, and obtain the general conclusions about discharge area.Then,by taking domestic present status into account,we introduce the inertial venting system and light friable system of the buildings,and analyze the current problems existing in the venting system.Finally,we put forward the future development direction for the venting system of buildings.
- Copyright
- © 2015, the Authors. Published by Atlantis Press.
- Open Access
- This is an open access article distributed under the CC BY-NC license (http://creativecommons.org/licenses/by-nc/4.0/).
Cite this article
TY - CONF AU - Tianhui Zhao AU - Ruliang Zheng PY - 2015/07 DA - 2015/07 TI - The Buildings Explosion Venting Research For The Gas Resource Utilization BT - Proceedings of the 3rd International Conference on Advances in Energy and Environmental Science 2015 PB - Atlantis Press SP - 1264 EP - 1268 SN - 2352-5401 UR - https://doi.org/10.2991/icaees-15.2015.235 DO - 10.2991/icaees-15.2015.235 ID - Zhao2015/07 ER -