Improvement on accuracy of coiling temperature at tail of strip during U-type cooling process
- DOI
- 10.2991/icadme-15.2015.310How to use a DOI?
- Keywords
- Coiling temperature, U-type cooling, water flow, number of valves turned on
- Abstract
Water flow and number of valves turned on were analyzed in order to find out the reason of low coiling temperature at tail of strip during U-type cooling process. Result of research showed that actual value of number of valves turned on in micro zone at tail of strip was not consistent with the corresponding calculated value of valves turned on. Then actual value of water flow at tail of strip was not consistent with the corresponding calculated value of water flow. That was the reason of low coiling temperature at tail of strip during U-type cooling process. The improvement measure was compensation adjustment for response time of valves. After improving, actual value of number of valves turned on in micro zone was consistent with the corresponding calculated value of valves turned on and high accuracy of coiling temperature at tail of strip was obtained.
- Copyright
- © 2015, the Authors. Published by Atlantis Press.
- Open Access
- This is an open access article distributed under the CC BY-NC license (http://creativecommons.org/licenses/by-nc/4.0/).
Cite this article
TY - CONF AU - Zhimin Zhang AU - Changli Zhang AU - Fengqin Wang AU - Yanhui Hu AU - Jinsheng Yang PY - 2015/10 DA - 2015/10 TI - Improvement on accuracy of coiling temperature at tail of strip during U-type cooling process BT - Proceedings of the 5th International Conference on Advanced Design and Manufacturing Engineering PB - Atlantis Press SP - 1674 EP - 1680 SN - 2352-5401 UR - https://doi.org/10.2991/icadme-15.2015.310 DO - 10.2991/icadme-15.2015.310 ID - Zhang2015/10 ER -