Safety assessment of steel framework of a utility boiler
- DOI
- 10.2991/icadme-15.2015.126How to use a DOI?
- Keywords
- safety assessment, steel framework, finite element analysis, seismic loads.
- Abstract
The steel framework of a utility boiler was an important structure sustained loads, and its strength and stiffness were primary factors in structural design. Stiffness was assessed by measuring perpendicularity of pillars. For this steel framewok seismic loads was significant to the entire strength. In order to refer to the influence of seismic loads, finite element method was adopted to analyze the strength of the whole steel framework. According to the results of finite element analysis, the maximum equivalent stress was 102.9MPa, which could satisfy the strength requirement. It indicated that this steel framework could satisfy the requirement of practical working conditions.
- Copyright
- © 2015, the Authors. Published by Atlantis Press.
- Open Access
- This is an open access article distributed under the CC BY-NC license (http://creativecommons.org/licenses/by-nc/4.0/).
Cite this article
TY - CONF AU - Bin Xu AU - Enpin Liu AU - Jingdong Wang AU - Liangsheng Chen PY - 2015/10 DA - 2015/10 TI - Safety assessment of steel framework of a utility boiler BT - Proceedings of the 5th International Conference on Advanced Design and Manufacturing Engineering PB - Atlantis Press SP - 622 EP - 627 SN - 2352-5401 UR - https://doi.org/10.2991/icadme-15.2015.126 DO - 10.2991/icadme-15.2015.126 ID - Xu2015/10 ER -