Proceedings of the 2023 9th International Conference on Architectural, Civil and Hydraulic Engineering (ICACHE 2023)

Architectural Design of Large Terminal Building Based on Embedded Multifunctional Security Warning System

Authors
Jiayin Li1, *
1China Aviation Planning and Design Institute(Group)Co., Ltd., Beijing, 100120, China
*Corresponding author. Email: gougouljy@163.com
Corresponding Author
Jiayin Li
Available Online 30 December 2023.
DOI
10.2991/978-94-6463-336-8_47How to use a DOI?
Keywords
Embedded; Multifunctional; Security early warning system; Architectural design of large terminal building
Abstract

In recent years, with the rapid development of the global aviation industry, the safety problems of large terminal buildings have become increasingly prominent. In order to ensure the safe and smooth operation of the terminal building, based on the application concept of embedded multifunctional security early warning system, this study puts forward an innovative multifunctional security early warning system for large terminal buildings. The hardware structure includes main control module, sensor, camera, audio equipment, network module, power management module, control panel and storage device. The functional modules work in coordination to expand the coverage of monitoring equipment. In the software part, the ant colony algorithm is used to establish the embedded multi-functional security system database, calculate the migration probability caused by the movement of two query nodes, obtain the weight of query paths, and stop updating pheromones. The fuzzy subset of data is determined in the embedded multi-functional security system database, and its membership function is calculated to realize the multi-functional security early warning of large terminal buildings. The experiment takes the international terminal reconstructed from T1 terminal of an international airport as the experimental object, with the reconstructed area of 24000m2 and the throughput of 880,000 passengers. The experimental results show that the average false alarm rate of this method is low, and the safety early warning effect of medium and large terminal buildings is good in practical application.

Copyright
© 2023 The Author(s)
Open Access
Open Access This chapter is licensed under the terms of the Creative Commons Attribution-NonCommercial 4.0 International License (http://creativecommons.org/licenses/by-nc/4.0/), which permits any noncommercial use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons license and indicate if changes were made.

Download article (PDF)

Volume Title
Proceedings of the 2023 9th International Conference on Architectural, Civil and Hydraulic Engineering (ICACHE 2023)
Series
Advances in Engineering Research
Publication Date
30 December 2023
ISBN
10.2991/978-94-6463-336-8_47
ISSN
2352-5401
DOI
10.2991/978-94-6463-336-8_47How to use a DOI?
Copyright
© 2023 The Author(s)
Open Access
Open Access This chapter is licensed under the terms of the Creative Commons Attribution-NonCommercial 4.0 International License (http://creativecommons.org/licenses/by-nc/4.0/), which permits any noncommercial use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons license and indicate if changes were made.

Cite this article

TY  - CONF
AU  - Jiayin Li
PY  - 2023
DA  - 2023/12/30
TI  - Architectural Design of Large Terminal Building Based on Embedded Multifunctional Security Warning System
BT  - Proceedings of the 2023 9th International Conference on Architectural, Civil and Hydraulic Engineering (ICACHE 2023)
PB  - Atlantis Press
SP  - 409
EP  - 416
SN  - 2352-5401
UR  - https://doi.org/10.2991/978-94-6463-336-8_47
DO  - 10.2991/978-94-6463-336-8_47
ID  - Li2023
ER  -