Research on impact factor of the HPA power synthesizes
- DOI
- 10.2991/fmsmt-17.2017.175How to use a DOI?
- Keywords
- Reflection power; transmission line; impedance matching
- Abstract
In aerospace measurement and control systems, solid-state power amplifier as an important part of the monitoring and control stations for the monitoring station to launch the carrier to provide high enough power to meet the required system EIRP. In this paper, the basic concept and principle of the transmission line are analyzed, and the method of solving the problem is put forward according to the actual situation of the solid - state power amplifier of the transmitting sub - system: 1). Based on the transmission line impedance matching technology, the transmission line impedance mismatch problem is solved. 2). Add phase shift components, to solve the transmission line between the phase match inconsistencies.
- Copyright
- © 2017, the Authors. Published by Atlantis Press.
- Open Access
- This is an open access article distributed under the CC BY-NC license (http://creativecommons.org/licenses/by-nc/4.0/).
Cite this article
TY - CONF AU - Gang Cheng AU - Chao Dai AU - Shuai Liu PY - 2017/04 DA - 2017/04 TI - Research on impact factor of the HPA power synthesizes BT - Proceedings of the 2017 5th International Conference on Frontiers of Manufacturing Science and Measuring Technology (FMSMT 2017) PB - Atlantis Press SP - 918 EP - 921 SN - 2352-5401 UR - https://doi.org/10.2991/fmsmt-17.2017.175 DO - 10.2991/fmsmt-17.2017.175 ID - Cheng2017/04 ER -