Analysis on Influence of Environmental Factors to the Heat Loss of Petrochemical Heating Furnace Wall
- DOI
- 10.2991/emim-16.2016.211How to use a DOI?
- Keywords
- Heating furnace; Wall of heating furnace; Heat loss; Infrared thermography
- Abstract
As some workers in petrochemical enterprise usually take the outside wall temperature as a standard to determine the thermal insulation effects of the equipments, this paper discussed the influence of environment factors, as the temperature and wind speed to the heat loss of petrochemical heating furnace wall. Infrared thermographic technique was used to track and monitor the radiation section wall temperature of a delayed coking furnace. The result shows that environmental factors have drastic effects on the outside wall temperature, but less on the furnace wall heat loss. When evaluating the heat resistant property of a furnace can not only by its outside wall temperature, but by the actual calculating heat loss.
- Copyright
- © 2016, the Authors. Published by Atlantis Press.
- Open Access
- This is an open access article distributed under the CC BY-NC license (http://creativecommons.org/licenses/by-nc/4.0/).
Cite this article
TY - CONF AU - Fenghong Pan AU - Jianjun Lan PY - 2016/04 DA - 2016/04 TI - Analysis on Influence of Environmental Factors to the Heat Loss of Petrochemical Heating Furnace Wall BT - Proceedings of the 6th International Conference on Electronic, Mechanical, Information and Management Society PB - Atlantis Press SP - 1026 EP - 1029 SN - 2352-538X UR - https://doi.org/10.2991/emim-16.2016.211 DO - 10.2991/emim-16.2016.211 ID - Pan2016/04 ER -