Loss and Temperature Computation of Damper Bars at Asymmetric Load Condtions of a Large Tubular Hydro-Generator
Authors
Lan Xiao, Zhen-nan Fan
Corresponding Author
Lan Xiao
Available Online September 2012.
- DOI
- 10.2991/emeit.2012.382How to use a DOI?
- Keywords
- tubular hydro-generator, damper bar, loss and temperature, asymmetric load
- Abstract
In order to research the loss and heat of damper bars on the asymmetric load condtions, a multi-slice moving electromagnetic field-circuit coupling FE model of tubular hydro-generator and a 3D temperature field FE model of the rotor are built respectively. And the loss and heat of damper bars at the asymmetric load condtions are computed and analyzed by these modles. The research is helpful for improving design standard of the large hydro-generator.
- Copyright
- © 2012, the Authors. Published by Atlantis Press.
- Open Access
- This is an open access article distributed under the CC BY-NC license (http://creativecommons.org/licenses/by-nc/4.0/).
Cite this article
TY - CONF AU - Lan Xiao AU - Zhen-nan Fan PY - 2012/09 DA - 2012/09 TI - Loss and Temperature Computation of Damper Bars at Asymmetric Load Condtions of a Large Tubular Hydro-Generator BT - Proceedings of the 2nd International Conference on Electronic & Mechanical Engineering and Information Technology (EMEIT 2012) PB - Atlantis Press SP - 1720 EP - 1723 SN - 1951-6851 UR - https://doi.org/10.2991/emeit.2012.382 DO - 10.2991/emeit.2012.382 ID - Xiao2012/09 ER -