Proceedings of the International Conference on Education, Management, Commerce and Society

The Measurement and Evaluation of Standard DQE in Digital Radiography

Authors
Xiang Lu, Junyi Zhang
Corresponding Author
Xiang Lu
Available Online January 2015.
DOI
10.2991/emcs-15.2015.162How to use a DOI?
Keywords
Digital radiography; Flat panel detector; Detective quantum efficiency; Medical images measuring
Abstract

This study introduces the measurement and evaluation of the standard detective quantum efficiency in digital radiography. The detective quantum efficiency (DQE) is the most suitable parameter for describing the imaging performance of digital Radiography. DQE is defined as the squared ratio of the signal-to-noise ratio at the output to the signal-to- noise ratio at the input of digital radiography. In this study, the main work is to use some device to gain images, which used to obtain the modulation transfer function (MTF) and Noise Power Spectrum (NPS), according to the international standard IEC 62220-1. We also do some work about the algorithm of MTF and NPS. Finally we design a set of DQE assessment method which can be used in metrology and measurement of digital radiography. We define the test conditions as follows: RQA5 radiation quality, 21mmAl additional filtration. Experiment proved that DQE can show the basic properties of the flat panel detector in DR system. In the process of obtaining the DQE, the key performance parameters could be measured and normalized, which includes DQE, MTF, detector response curve and NPS. The digital radiography with poor DQE has the low imaging quality. The patients should have more body surface irradiation dose. Metrological verification and quality control personnel can determine the working station of DR system according to the indexes of DQE various performance indicators, which is good for decreasing collective effective dose equivalent.

Copyright
© 2015, the Authors. Published by Atlantis Press.
Open Access
This is an open access article distributed under the CC BY-NC license (http://creativecommons.org/licenses/by-nc/4.0/).

Download article (PDF)

Volume Title
Proceedings of the International Conference on Education, Management, Commerce and Society
Series
Advances in Social Science, Education and Humanities Research
Publication Date
January 2015
ISBN
978-94-62520-48-6
ISSN
2352-5398
DOI
10.2991/emcs-15.2015.162How to use a DOI?
Copyright
© 2015, the Authors. Published by Atlantis Press.
Open Access
This is an open access article distributed under the CC BY-NC license (http://creativecommons.org/licenses/by-nc/4.0/).

Cite this article

TY  - CONF
AU  - Xiang Lu
AU  - Junyi Zhang
PY  - 2015/01
DA  - 2015/01
TI  - The Measurement and Evaluation of Standard DQE in Digital Radiography
BT  - Proceedings of the International Conference on Education, Management, Commerce and Society
PB  - Atlantis Press
SP  - 790
EP  - 794
SN  - 2352-5398
UR  - https://doi.org/10.2991/emcs-15.2015.162
DO  - 10.2991/emcs-15.2015.162
ID  - Lu2015/01