Parameter identification and simulation of synchronous generator in an isolated power system
- DOI
- 10.2991/emcpe-16.2016.139How to use a DOI?
- Keywords
- Parameter identification; Synchronous generator; Isolated Power system; MATLAB
- Abstract
The parameter estimation of a synchronous generator using the still frequency responses is presented in this paper. The required data is obtained to estimate the electrical parameters of the direct and quadrate axis models and the complete set of parameters was used in a five-order simulation model for a synchronous machine. To check the validity of the estimated parameters, the impact load simulation experiment is carried out at the generator terminals. A synchronous generator rate 120kVA, 400V, 1500 rpm, 50 Hz was used in the investigation. The measured data are compared with the simulation response of the generator model using the parameters estimated from the still frequency response, which can be seen that the data of simulation and the data of experimental match accurately.
- Copyright
- © 2016, the Authors. Published by Atlantis Press.
- Open Access
- This is an open access article distributed under the CC BY-NC license (http://creativecommons.org/licenses/by-nc/4.0/).
Cite this article
TY - CONF AU - Pu Xie AU - Man Cao AU - Zhengchun Liu PY - 2016/08 DA - 2016/08 TI - Parameter identification and simulation of synchronous generator in an isolated power system BT - Proceedings of the 2016 5th International Conference on Environment, Materials, Chemistry and Power Electronics PB - Atlantis Press SP - 506 EP - 512 SN - 2352-5401 UR - https://doi.org/10.2991/emcpe-16.2016.139 DO - 10.2991/emcpe-16.2016.139 ID - Xie2016/08 ER -