The Preliminary Investigation of Needle Plate Electrode Discharge Characteristics in the Oil under Impulse Voltage
- DOI
- 10.2991/eame-17.2017.3How to use a DOI?
- Keywords
- impulse voltage; solid-state switch; partial discharge; photomultiplier; streamer
- Abstract
Partial discharge detection under impulse voltage is an effective method for monitoring the insulating properties and the aging of high-voltage electric equipment. It is of great practical significance for discovering potential safety hazard in time and ensuring the safe operation of equipment. In this paper, we set up an impulse voltage source with solid-state switch, the discharge signals of needle plate electrode in the oil are detected by using the photomultiplier. The results show that the measurement can successfully detect the discharge signal both in the wave head and the wave tail, the signals in the wave head usually have a long duration, intensely and constantly discharge; the signals in the wave tail usually have a short duration, weakly and discontinuity discharge. We make the analysis with a possible mechanism of physical aiming at this phenomenon.
- Copyright
- © 2017, the Authors. Published by Atlantis Press.
- Open Access
- This is an open access article distributed under the CC BY-NC license (http://creativecommons.org/licenses/by-nc/4.0/).
Cite this article
TY - CONF AU - Liangliang Hua AU - Jidong Wei AU - Jun Zhang AU - Bo Kong AU - Mingchang Liu AU - Jianhong Guo PY - 2017/04 DA - 2017/04 TI - The Preliminary Investigation of Needle Plate Electrode Discharge Characteristics in the Oil under Impulse Voltage BT - Proceedings of the 2017 2nd International Conference on Electrical, Automation and Mechanical Engineering (EAME 2017) PB - Atlantis Press SP - 9 EP - 12 SN - 2352-5401 UR - https://doi.org/10.2991/eame-17.2017.3 DO - 10.2991/eame-17.2017.3 ID - Hua2017/04 ER -