Sensorless Vibration Diagnostics of Permanent Magnets Traction Electrical Motors–The Shaft Unbalance Example
- DOI
- 10.2991/eame-15.2015.132How to use a DOI?
- Keywords
- vibrations; diagnostics; monitoring; electrical machine; permanent magnets
- Abstract
This work presents a new vibration diagnostic method of permanent magnets (PM) traction motors. Those machines are frequently used in electrical vehicles. The described method is very unique and innovative. Characteristic properties of PM machines are used in this method - EMF generated due to vibrations. There was analysed number of publications which describe vibration diagnostic methods and tests of electrical machines with permanent magnets and there was no method found to determine the technical condition of such machine basing on their own signals. The method of determination the technical condition of PM electrical machine basing on its own signals is the subject of patent application [1].
- Copyright
- © 2015, the Authors. Published by Atlantis Press.
- Open Access
- This is an open access article distributed under the CC BY-NC license (http://creativecommons.org/licenses/by-nc/4.0/).
Cite this article
TY - CONF AU - M. Baranski AU - B. Bedkowski PY - 2015/07 DA - 2015/07 TI - Sensorless Vibration Diagnostics of Permanent Magnets Traction Electrical Motors–The Shaft Unbalance Example BT - Proceedings of the 2015 International Conference on Electrical, Automation and Mechanical Engineering PB - Atlantis Press SP - 466 EP - 468 SN - 2352-5401 UR - https://doi.org/10.2991/eame-15.2015.132 DO - 10.2991/eame-15.2015.132 ID - Baranski2015/07 ER -