Research on the Calibration System of Noncontact Electrostatic Voltmeter by Using the Finite Element Analysis
Authors
Jieyu Liu, Wenzuo Ma, Rundan Zhang, Yidan Zhang, Jianning He
Corresponding Author
Jieyu Liu
Available Online April 2018.
- DOI
- 10.2991/cmsa-18.2018.46How to use a DOI?
- Keywords
- calibration; electrostatic voltmeter; finite element method; noncontact measurement
- Abstract
Noncontact measurement of electrostatic voltage is required to study the charges in HVDC transmission system. The calibration platform of noncontact electrostatic voltmeter is studied. The electric field near the measurement probe is calculated by FEM. Based on the calculation, the edge effect and applied voltage of the calibrating plate electrode are analyzed.
- Copyright
- © 2018, the Authors. Published by Atlantis Press.
- Open Access
- This is an open access article distributed under the CC BY-NC license (http://creativecommons.org/licenses/by-nc/4.0/).
Cite this article
TY - CONF AU - Jieyu Liu AU - Wenzuo Ma AU - Rundan Zhang AU - Yidan Zhang AU - Jianning He PY - 2018/04 DA - 2018/04 TI - Research on the Calibration System of Noncontact Electrostatic Voltmeter by Using the Finite Element Analysis BT - Proceedings of the 2018 International Conference on Computer Modeling, Simulation and Algorithm (CMSA 2018) PB - Atlantis Press SP - 199 EP - 203 SN - 1951-6851 UR - https://doi.org/10.2991/cmsa-18.2018.46 DO - 10.2991/cmsa-18.2018.46 ID - Liu2018/04 ER -