Modeling and Analysis of Electrical Connectors in Salt Spray Environment
- DOI
- 10.2991/cmsa-18.2018.6How to use a DOI?
- Keywords
- electrical connectors; modeling; salt spray test
- Abstract
As a basic component, electrical connectors play a major role in the transmission and control of electric signals. In this paper, SubMiniature version A (SMA) coaxial connectors, which are widely used in the microwave equipment and radio frequency circuits, were taken as the research objects to investigate the deg-radation of electrical connectors in salt spray environment. The simulation model was built to analyze the failure mechanism. An accelerated test was conducted to study its electrical contact prop-erties and obtain the degradation data. The experimental and simulation results showed consistent trends. Accordingly, the degradation of the high-frequency performance for the electrical connector in the salt spray environment is mainly due to the for-mation of corrosion film on the contact surface.
- Copyright
- © 2018, the Authors. Published by Atlantis Press.
- Open Access
- This is an open access article distributed under the CC BY-NC license (http://creativecommons.org/licenses/by-nc/4.0/).
Cite this article
TY - CONF AU - Lin Guan AU - Yuanlong Li AU - Chendi Feng AU - Qingya Li AU - Yuqi Zhou AU - Jinchun Gao PY - 2018/04 DA - 2018/04 TI - Modeling and Analysis of Electrical Connectors in Salt Spray Environment BT - Proceedings of the 2018 International Conference on Computer Modeling, Simulation and Algorithm (CMSA 2018) PB - Atlantis Press SP - 21 EP - 24 SN - 1951-6851 UR - https://doi.org/10.2991/cmsa-18.2018.6 DO - 10.2991/cmsa-18.2018.6 ID - Guan2018/04 ER -