Design and Optimization of Boiler Economizer for Laundry Industry Using Taguchi Method
- DOI
- 10.2991/assehr.k.200529.111How to use a DOI?
- Keywords
- boiler economizer, laundry industry, taguchi method
- Abstract
The exhaust gas from the boiler in the laundry industry can reach more than 300°C. The potential energy can be converted to increase the temperature of feed water through a heat exchanger. In this study, a shell and tube heat exchanger was chosen to increase the feed water temperature with the flow rate of 0.55 kg/s to reach the target of 80°C. Meanwhile, the mass flow rate of the exhaust gas is 0.9 kg/s with a temperature estimated at 300 - 310°C. The basic design of the heat exchanger is created to get the main dimensions such as the cross-sectional area (A), the length of the tube (L), the outer diameter of the tube (do) and the total of tube (N). Finally, the main dimensions are optimized by the Taguchi experimental method to obtain the most optimal design.
- Copyright
- © 2020, the Authors. Published by Atlantis Press.
- Open Access
- This is an open access article distributed under the CC BY-NC license (http://creativecommons.org/licenses/by-nc/4.0/).
Cite this article
TY - CONF AU - Khoirul Anam AU - La Ode Mohammad Firman PY - 2020 DA - 2020/05/04 TI - Design and Optimization of Boiler Economizer for Laundry Industry Using Taguchi Method BT - Proceedings of the 1st Borobudur International Symposium on Humanities, Economics and Social Sciences (BIS-HESS 2019) PB - Atlantis Press SP - 533 EP - 537 SN - 2352-5398 UR - https://doi.org/10.2991/assehr.k.200529.111 DO - 10.2991/assehr.k.200529.111 ID - Anam2020 ER -