Steady-State Modeling of the Refrigeration Unit for a Marine Refrigerated Container
- DOI
- 10.2991/ap3er-15.2015.16How to use a DOI?
- Keywords
- marine refrigerated container; refrigeration unit; simulation; steady-state model; full-load experiment
- Abstract
The mathematical models of compressor, evaporator and condenser in a refrigerated container’s refrigeration unit were established, which were used to form the whole system model for steady-state simulation according to the coupling relationship among them. The full-load performance of the refrigeration system was firstly deployed using the system model programmed in the MATLAB software. And the experimental performance tests were secondly carried out using a marine refrigerated container test rig. The errors between simulation results and experimental results are within 10%. Therefore the model has good simulation accuracy and could be used for the future energy-saving analysis of the marine refrigerated container.
- Copyright
- © 2015, the Authors. Published by Atlantis Press.
- Open Access
- This is an open access article distributed under the CC BY-NC license (http://creativecommons.org/licenses/by-nc/4.0/).
Cite this article
TY - CONF AU - Jiajun Ren AU - Chaoyu Zheng AU - Wu Chen PY - 2015/06 DA - 2015/06 TI - Steady-State Modeling of the Refrigeration Unit for a Marine Refrigerated Container BT - Proceedings of the 2015 Asia-Pacific Energy Equipment Engineering Research Conference PB - Atlantis Press SP - 64 EP - 68 SN - 2352-5401 UR - https://doi.org/10.2991/ap3er-15.2015.16 DO - 10.2991/ap3er-15.2015.16 ID - Ren2015/06 ER -