A Mixed Normalization Capacitance Model for Electrical Capacitance Tomography
- DOI
- 10.2991/ameii-16.2016.104How to use a DOI?
- Keywords
- Electrical resistance tomography, image reconstruction, capacitance normalization.
- Abstract
Electrical capacitance tomography (ECT) is a technique developed in recent 30 years, which aims to measure multi-phase flow. The image reconstruction for ECT is an inverse problem to find the permittivity distribution in a pipe. The normalized capacitance measurements are needed during the process of image reconstruction. Parallel normalization model is the most commonly used normalization model, and series normalization model was also studied by some researchers. In this paper, a mixed normalization model based on electrical field center line (EFCL) and multi-threshold method was presented. The sensitivity matrices based on different normalization models were obtained and image reconstruction was carried out accordingly. Simulation and static experiment indicate that reconstructed images with higher quality can be obtained based on the presented model.
- Copyright
- © 2016, the Authors. Published by Atlantis Press.
- Open Access
- This is an open access article distributed under the CC BY-NC license (http://creativecommons.org/licenses/by-nc/4.0/).
Cite this article
TY - CONF AU - Lifeng Zhang AU - Feng Zhu AU - Qin Zhang PY - 2016/04 DA - 2016/04 TI - A Mixed Normalization Capacitance Model for Electrical Capacitance Tomography BT - Proceedings of the 2nd International Conference on Advances in Mechanical Engineering and Industrial Informatics (AMEII 2016) PB - Atlantis Press SP - 517 EP - 520 SN - 2352-5401 UR - https://doi.org/10.2991/ameii-16.2016.104 DO - 10.2991/ameii-16.2016.104 ID - Zhang2016/04 ER -