Failure analysis of steam pipe flange gasket
Authors
Wei Liu, HeHui Wang
Corresponding Author
Wei Liu
Available Online March 2017.
- DOI
- 10.2991/amcce-17.2017.73How to use a DOI?
- Keywords
- serrated gasket, failure analysis, residual stress.
- Abstract
Flange at the end of steam line in the Co coking joint unit became invalid in a normal operation at a petrochemical corporation. The failure mechanism was fatigue fracture failure by means of gasket macro analysis, chemical composition analysis, metallographic analysis, fracture analysis and energy spectrum analysis. The reason was that residual stress existed in serrated gasket. The improving measure was put forward to prevent the failure in serrated gasket.
- Copyright
- © 2017, the Authors. Published by Atlantis Press.
- Open Access
- This is an open access article distributed under the CC BY-NC license (http://creativecommons.org/licenses/by-nc/4.0/).
Cite this article
TY - CONF AU - Wei Liu AU - HeHui Wang PY - 2017/03 DA - 2017/03 TI - Failure analysis of steam pipe flange gasket BT - Proceedings of the 2017 2nd International Conference on Automation, Mechanical Control and Computational Engineering (AMCCE 2017) PB - Atlantis Press SP - 422 EP - 425 SN - 2352-5401 UR - https://doi.org/10.2991/amcce-17.2017.73 DO - 10.2991/amcce-17.2017.73 ID - Liu2017/03 ER -