Numerical Analysis on Influence of Underground Space Construction on Adjacent Tunnel
- DOI
- 10.2991/aeece-15.2015.118How to use a DOI?
- Keywords
- adjacent tunnel; underground space; interaction; numerical analysis
- Abstract
The construction of underground engineering will bring risks and potential hazards to the adjacent tunnel engineering. A series of numerical analysis models have been built to analyze the influence of underground engineering construction having on adjacent tunnel structure under different horizontal distance. According the simulation results, when the distance from underground space to tunnel is less than 10m, the interaction is fairly remarkable. It is suggested to take strong pre-consolidation measure during the construction of tunnel. The critical distance of underground space to adjacent tunnel is about 20m. When the distance is less than 20m, the adverse effect must be taken into consideration during the design and construction of adjacent tunnels.
- Copyright
- © 2015, the Authors. Published by Atlantis Press.
- Open Access
- This is an open access article distributed under the CC BY-NC license (http://creativecommons.org/licenses/by-nc/4.0/).
Cite this article
TY - CONF AU - Jianwu Gong AU - Xin Wang AU - Hao Sheng PY - 2015/09 DA - 2015/09 TI - Numerical Analysis on Influence of Underground Space Construction on Adjacent Tunnel BT - Proceedings of the International Conference on Advances in Energy, Environment and Chemical Engineering PB - Atlantis Press SP - 592 EP - 595 SN - 2352-5401 UR - https://doi.org/10.2991/aeece-15.2015.118 DO - 10.2991/aeece-15.2015.118 ID - Gong2015/09 ER -