Artery Research

Volume 26, Issue Supplement 1, December 2020, Pages S69 - S69

P.46 Assessment of Intraplaque Hemorrhage by Photoacoustics Imaging (PAI): First in-vivo Human Validation Study

Authors
Rosa Maria Bruno1, *, Yuki Imaizumi2, Hasan Obeid, Michael Jaeger3, Pierre Julia1, Patrick Bruneval1, David Calvet2
1Inserm U970, Université de Paris
2Hôpital Sainte - Anne
3University of Bern
*Corresponding author. Email: rosam.bruno@gmail.com
Corresponding Author
Rosa Maria Bruno
Available Online 31 December 2020.
DOI
10.2991/artres.k.201209.058How to use a DOI?
Keywords
Carotid-plaque; photoacoustic; validation
Abstract

Aim: To validate a photoacoustic imaging (PAI) system, for the identification of intraplaque hemorrhage, comparing it with MRI and histology (gold standard).

Methods: 25 patients with carotid stenosis >70% and clinical indication to tromboendoarterectomy were recruited. Angio-MRI for intraplaque hemorrhage assessment (Cube sequence) was performed. PAI clips (5 seconds, Frame rate 1000/sec, 3 to 15 per patient) were acquired. Each clip was scored for the presence of PAI signal by means of an integrated scoring system (semiquantitative, from 0 to 12). Semiquantitative grading scales were used to assess plaque histological features of hemorrhage and vulnerability.

Results: 18 patients had no missing MRI, PAI and histology data and were included in this analysis. Mean age was 73 ± 8 years, 60% men, 80% Caucasians, 92% hypertensives, 60% with a previous stroke. At histology, only 3 plaques out of 21 showed no signs of intraplaque hemorrhage, 4 showed small hemorrhage, while 14 (67%) showed large hemorrhages. PAI score (best cut-off ≥ 4) correctly classified 14 out of 18 patients (Sensitivity = 73.3%, specificity = 100%, AUC = 0.867). MRI performance was substantially similar, with 12 patients correctly classified (sensitivity = 60%, specificity = 100%, AUC = 0.800), with a non-significant difference in AUC compared to PAI (p = 0.420).

Conclusions: In this first in-vivo human study, PAI is able to identify histological intraplaque hemorrhage with an excellent specificity and acceptable sensitivity, equivalent to MRI. The very high specificity, with a low number of false positives, make PAI a good candidate for evaluation of plaques prior to surgery to i.e. reinforce the decision to perform surgery.

Copyright
© 2020 Association for Research into Arterial Structure and Physiology. Publishing services by Atlantis Press International B.V.
Open Access
This is an open access article distributed under the CC BY-NC 4.0 license (http://creativecommons.org/licenses/by-nc/4.0/).

Journal
Artery Research
Volume-Issue
26 - Supplement 1
Pages
S69 - S69
Publication Date
2020/12/31
ISSN (Online)
1876-4401
ISSN (Print)
1872-9312
DOI
10.2991/artres.k.201209.058How to use a DOI?
Copyright
© 2020 Association for Research into Arterial Structure and Physiology. Publishing services by Atlantis Press International B.V.
Open Access
This is an open access article distributed under the CC BY-NC 4.0 license (http://creativecommons.org/licenses/by-nc/4.0/).

Cite this article

TY  - JOUR
AU  - Rosa Maria Bruno
AU  - Yuki Imaizumi
AU  - Hasan Obeid
AU  - Michael Jaeger
AU  - Pierre Julia
AU  - Patrick Bruneval
AU  - David Calvet
PY  - 2020
DA  - 2020/12/31
TI  - P.46 Assessment of Intraplaque Hemorrhage by Photoacoustics Imaging (PAI): First in-vivo Human Validation Study
JO  - Artery Research
SP  - S69
EP  - S69
VL  - 26
IS  - Supplement 1
SN  - 1876-4401
UR  - https://doi.org/10.2991/artres.k.201209.058
DO  - 10.2991/artres.k.201209.058
ID  - Bruno2020
ER  -