P3.31 CORRELATION OF CENTRAL HAEMODYNAMICS WITH HEALTH-RELATED QUALITY OF LIFE
- DOI
- 10.1016/j.artres.2013.10.118How to use a DOI?
- Abstract
Objectives: High blood pressure (BP) levels have been reported to have an inverse association with the health-related quality of life (HRQOL). Moreover, the value of central beyond peripheral haemodynamics has been illustrated by a series of studies. We sought to investigate potential correlations between central haemodynamics and HRQOL.
Methods: Brachial BP was evaluated with an automatic, oscillometric device (WatchBP, Microlife). Central haemodynamics (aortic BP, augmentation index (AIx), augmentation pressure (AP)) were assessed using applanation tonometry (SphygmoCor, AtCor). For HRQOL assessment the EQ5D instrument was utilized. EQ5D estimates five dimensions (mobility; self-care; usual activities; pain/discomfort; anxiety/depression) which are subdivided in three severity levels. These dimensions are transformed in an overall index, MVH-York-A1-tariff (0=worst, 1=best). Additionally, EQ5D involves a visual analogue scale (VAS) in which respondents self-rate their health state (0=worst, 100=best).
Results: A hundred and fifty consecutive subjects (80 males; 55±15 years old; BMI: 27.3±4.4 kg/m2, 49% hypertensives, 10% diabetics) were included in the study. Average brachial/ aortic SBP was 131±16/ 121±17 mmHg, DBP was 78±9/ 79±9 mmHg. Average AIx/ AIx75bpm was 28.8±14.6/ 23.3±14.3, AP/ AP@75bpm 13.2±8.1/ 9.8±6.7 mmHg. Mean MVH-York-A1-tariff was 0.85±0.18, while VAS was 78.3±13.6. Peripheral haemodynamics were correlated neither with MVH-York-A1-tariff nor with VAS. However, a negative correlation between aortic SBP, AIx, AIx@75, AP, AP@75 and HRQOL indices was observed (Table).
Conclusions: In the present study, aortic SBP, AIx and AP were found to negatively correlate with HRQOL.
HRQOL indices & haemodynamics MVH York A1 tariff VAS C.C. p C.C. p Brachial SBP, mmHg 0,008 0,928 −0,099 0,238 Brachial DBP, mmHg 0,074 0,377 −0,103 0,218 Aortic SBP, mmHg −0,061 0,469 −0,193* 0,020 Aortic DBP, mmHg 0,078 0,348 −0,102 0,221 AIx −0,246** 0,003 −0,297** <0,001 AIx @75bpm −0,240** 0,004 −0,298** <0,001 AP, mmHg −0,218** 0,008 −0,299** <0,001 AP @75bpm, mmHg −0,199* 0,016 −0,298** <0,001 AIx: Augmentation Index; AP: Augmentation Pressure; CC: Correlation Coefficient; DBP: Diastolic Blood Pressure; MBP: Mean Blood Pressure; PWV: Pulse Wave Velocity; SBP: Systolic Blood Pressure level of significance:
*0.05,
**0.01
- Open Access
- This is an open access article distributed under the CC BY-NC license.
Cite this article
TY - JOUR AU - D.A. Vrachatis AU - A. Argyris AU - A. Papadopoulos AU - T.G. Papaioannou AU - E. Aissopou AU - G. Konstantonis AU - D. Niakas AU - P. Sfikakis AU - A. Protogerou PY - 2013 DA - 2013/11/11 TI - P3.31 CORRELATION OF CENTRAL HAEMODYNAMICS WITH HEALTH-RELATED QUALITY OF LIFE JO - Artery Research SP - 135 EP - 135 VL - 7 IS - 3-4 SN - 1876-4401 UR - https://doi.org/10.1016/j.artres.2013.10.118 DO - 10.1016/j.artres.2013.10.118 ID - Vrachatis2013 ER -