Artery Research

Volume 7, Issue 3-4, September 2013, Pages 121 - 121

P2.08 ESTIMATION OF LONGITUDINAL WALL MOVEMENT IN COMMON CAROTID ARTERY USING ROBUST BLOCK-MATCHING WITH AN EXTRA BLOCK

Authors
J. Albinsson1, Å.R. Ahlgren2, M. Cinthio1
1Electrical Measurement, Faculty of Engineering, Lund University, Lund, Sweden
2Clinical Physiology and Nuclear Medicine Unit, Department of Clinical Sciences, Lund University, Malmo, Sweden
Available Online 11 November 2013.
DOI
10.1016/j.artres.2013.10.070How to use a DOI?
Abstract

Technological developments made it possible to detect a longitudinal motion of the arterial wall. Our previously presented method can estimate this motion with high accuracy, but the method requires ultrasound images of very high quality. The aim of this study was to evaluate a novel method for estimating the longitudinal movement with respect to both robustness and accuracy.

The developed method uses ultrasound B-mode information to give a sub-pixel estimation of the movement of an area chosen in a cineloop. The method was evaluated in vivo on the right common carotid artery of healthy volunteers (2 measurements each on 10 males; age 27–57 years and 10 females; age 25–49 years).

Figure 1 shows the longitudinal arterial wall movement of one volunteer. Three phases of longitudinal wall movement can be detected; an antegrade movement (LMov1) in early systole, a following retrograde movement (LMov2), and a subsequent antegrade movement (LMov3). The magnitude of the three phases of movement was mean 312 μm (SD 197), −706 μm (222) and 577 μm (218), respectively. The intra-observer variation for the different phases of movement was 21%, 13%, and 17%, respectively, compared to 14%, 13%, and 16% using our previously presented method. Figure 2 shows a Bland-Altman plot comparing the two methods. While the new method could make estimations in all cineloops, our previously presented method failed in six of them.

The study shows that the new method seems to be more robust than our previously presented method with similar tracking accuracy.

Open Access
This is an open access article distributed under the CC BY-NC license.

Journal
Artery Research
Volume-Issue
7 - 3-4
Pages
121 - 121
Publication Date
2013/11/11
ISSN (Online)
1876-4401
ISSN (Print)
1872-9312
DOI
10.1016/j.artres.2013.10.070How to use a DOI?
Open Access
This is an open access article distributed under the CC BY-NC license.

Cite this article

TY  - JOUR
AU  - J. Albinsson
AU  - Å.R. Ahlgren
AU  - M. Cinthio
PY  - 2013
DA  - 2013/11/11
TI  - P2.08 ESTIMATION OF LONGITUDINAL WALL MOVEMENT IN COMMON CAROTID ARTERY USING ROBUST BLOCK-MATCHING WITH AN EXTRA BLOCK
JO  - Artery Research
SP  - 121
EP  - 121
VL  - 7
IS  - 3-4
SN  - 1876-4401
UR  - https://doi.org/10.1016/j.artres.2013.10.070
DO  - 10.1016/j.artres.2013.10.070
ID  - Albinsson2013
ER  -