Artery Research

Volume 20, Issue C, December 2017, Pages 79 - 79

P124 VALIDITY AND RELIABILITY OF PULSE WAVE ANALYSIS ESTIMATED BY A NOVEL WRIST-WORN TONOMETER

Authors
Luis Garcia-Ortiz1, 2, Jose Recio-Rodriguez1, 3, Cristina Agudo-Conde1, Rita Salvado1, Jose Maderuelo-Fernandez1, Jesus Gonzalez-Sanchez4, 5, Emiliano Rodriguez- Sanches1, 6, Manuel Gómez-Marcos1, 6, on behalf EVA_Investigators6
1Primary Health Care Research Unit, La Alamedilla Health Center, Health Service of Castilla y León (SACyL), Biomedical Research Institute of Salamanca (IBSAL), Salamanca, Spain
2Department of Biomedical and Diagnostic Sciences, University of Salamanca, Salamanca, Spain
3Department of Nurse and Physiotherapy, University of Salamanca, Salamanca, Spain
4Primary Care Research Unit, The Alamedilla Health Center, Castilla and León Health Service (SACYL), Biomedical Research Institute of Salamanca (IBSAL)
5Department of Nursing, University of Extremadura, Plasencia, Cáceres, Spain
6Department of Medicine, University of Salamanca, Salamanca, Spain
Available Online 6 December 2017.
DOI
10.1016/j.artres.2017.10.106How to use a DOI?
Abstract

Objective: To analyze the reliability and validity of Pulse Wave Analysis determined with the new wrist-worn tonometry.

Methods: Cross sectional study including 254 subjects. Aged 51.9±13.4, being women 53%. Main measurements: Peripheral AIx (PAIx) and Central AIx (CAIx) by wrist-worn tonometry and Sphygmocor. Carotid femoral (cf) pulse wave velocity (PWV) by Sphygmocor, Cardio Anckle Vascular index (CAVI), anckle brachial index (ABI) and brachial anckle (ba) PWV by Vasera device. Carotid intima media thickness (IMT) by ultrasonography.

Results: Intra-class correlation coefficient (ICC) intraobserver for the PAIx was 0.886 (95% CI 0.803 to 0.934) and for the CAIx 0.943 (0.901 to 0.968) with a Bland Almant agreement limit of −0.75 (−23.8 to 21.8) and 0.08 (−15.7 to 15.9) respectively. ICC interobserver for PAIx was 0.952 (95% CI 0.915 to 0.972) and CAIx 0.893 (0.811 to 0.939) with an agreement limit of −0.45 (−13.7 to 12.8) and 0.43 (−17.7 to 1835) respectively. We found, compared with Sphygmocor, an ICC of 0.849 (0.798 to 0.887) for PAIx, and 0.783 (0.711 to 0.838) for CAIx. The agreement limit for PAIx was −1.03 (−22.73 to 20.67) and CAIx 2.14 (−20.50 to 24.79). We found positive correlation with PAIx, CAIx and CAIx HR75 by Aurora with age, CAVI, ABI, baPWV, cfPWV, IMT and cardiovascular risk and negative with glomerular filtration rate.

Conclusions: The wrist-worn tonometry shows an adequate reliability intra and interobserver, and interdevice when compared to Sphygmocor, and an adequate validity when compared with other measures that evaluate arterial stiffness, target organ damage and cardiovascular risk.

Open Access
This is an open access article distributed under the CC BY-NC license.

Journal
Artery Research
Volume-Issue
20 - C
Pages
79 - 79
Publication Date
2017/12/06
ISSN (Online)
1876-4401
ISSN (Print)
1872-9312
DOI
10.1016/j.artres.2017.10.106How to use a DOI?
Open Access
This is an open access article distributed under the CC BY-NC license.

Cite this article

TY  - JOUR
AU  - Luis Garcia-Ortiz
AU  - Jose Recio-Rodriguez
AU  - Cristina Agudo-Conde
AU  - Rita Salvado
AU  - Jose Maderuelo-Fernandez
AU  - Jesus Gonzalez-Sanchez
AU  - Emiliano Rodriguez- Sanches
AU  - Manuel Gómez-Marcos
AU  - on behalf EVA_Investigators
PY  - 2017
DA  - 2017/12/06
TI  - P124 VALIDITY AND RELIABILITY OF PULSE WAVE ANALYSIS ESTIMATED BY A NOVEL WRIST-WORN TONOMETER
JO  - Artery Research
SP  - 79
EP  - 79
VL  - 20
IS  - C
SN  - 1876-4401
UR  - https://doi.org/10.1016/j.artres.2017.10.106
DO  - 10.1016/j.artres.2017.10.106
ID  - Garcia-Ortiz2017
ER  -