Artery Research

Volume 24, Issue C, December 2018, Pages 83 - 84

P14 REFERENCE VALUES OF THE WEST SPANISH POPULATION OF THE HEMODYNAMIC INDICES EVALUATED WITH A NEW WRIST WORN DEVICE

Authors
Marta Gomez-Sanchez1, Leticia Gomez-Sanchez2, Rosario Alonso-Domínguez3, Jesus Gonzalez-Sanchez4, Cristina Agudo- Conde3, Natalia Sánchez-Aguadero3, Carmela Rodriguez-Martin5, Luis Garcia-Ortiz3
1Institute of Biomedical Research of Salamanca (IBSAL), Primary Health Care Research Unit, La Alamedilla Health Center, Salamanca, Spain
2Institute of Biomedical Research of Salamanca (IBSAL), Primary Health Care Research Unit, La Alamedilla Health Center, Salamanca, Spain
3Institute of Biomedical Research of Salamanca (IBSAL), Primary Health Care Research Unit, La Alamedilla Health Center, Health Service of Castilla y León (SACyL), Salamanca, Spain
4Institute of Biomedical Research of Salamanca (IBSAL), Primary Health Care Research Unit, La Alamedilla Health Center Health, Salamanca, Spain
5Institute of Biomedical Research of Salamanca (IBSAL), Primary Health Care Research Unit, La Alamedilla Health Center, Health Service of Castilla y León (SACyL), Salamanca, Spain
Available Online 4 December 2018.
DOI
10.1016/j.artres.2018.10.067How to use a DOI?
Abstract

Objective: To describe the reference value of arterial stiffness parameter measurement by wrist worn device (Microsoft) in west Spanish population.

Methods: Cross-sectional study. Study population: From the population assigned to the participating healthcare centres, a cluster random sampling stratified by age and gender was performed to obtain 501 participants aged between 35 and 75, 100 per decade, (50% women) without cardio or cerebrovascular disease. Measurements: Central (CAIx) and peripheral (PAIx) augmentation index, Heart rate (HR) and heart rate variability (HRV) by a new wrist worn device developed by Microsoft.

Results: Mean age was: 55.9 ± 14.2y. Mean PAIx was 91.22 ± 16.05, in women 95.34 ± 16.17 and in men 87.08 ± 14.86 (p0.05). The PAIx and CAIx increased with each decade, (PAIx was 79.85 in born in 1981 and 99.68 in born in 1941, and CAIx 19.25 in born in 1981 to 35.11 in born in 1941), and HRV decrease with each decade (3.31 in born in 1981 and 2.52 in born in 1941). No differences were found in heart rate. This data is the same in men and women. Correlation of age with PAIx was r = 0.424, CAIx r = 0.323, HRV r = -0.364 (p > 0.01 for all) and HR 0.51 (p > 0.05).

Conclusion: The PAIx and CAIx were higher in women than men. PAIx and CAIx increase with aging while the HRV decreases.

Open Access
This is an open access article distributed under the CC BY-NC license.

Download article (PDF)
View full text (HTML)

Journal
Artery Research
Volume-Issue
24 - C
Pages
83 - 84
Publication Date
2018/12/04
ISSN (Online)
1876-4401
ISSN (Print)
1872-9312
DOI
10.1016/j.artres.2018.10.067How to use a DOI?
Open Access
This is an open access article distributed under the CC BY-NC license.

Cite this article

TY  - JOUR
AU  - Marta Gomez-Sanchez
AU  - Leticia Gomez-Sanchez
AU  - Rosario Alonso-Domínguez
AU  - Jesus Gonzalez-Sanchez
AU  - Cristina Agudo- Conde
AU  - Natalia Sánchez-Aguadero
AU  - Carmela Rodriguez-Martin
AU  - Luis Garcia-Ortiz
PY  - 2018
DA  - 2018/12/04
TI  - P14 REFERENCE VALUES OF THE WEST SPANISH POPULATION OF THE HEMODYNAMIC INDICES EVALUATED WITH A NEW WRIST WORN DEVICE
JO  - Artery Research
SP  - 83
EP  - 84
VL  - 24
IS  - C
SN  - 1876-4401
UR  - https://doi.org/10.1016/j.artres.2018.10.067
DO  - 10.1016/j.artres.2018.10.067
ID  - Gomez-Sanchez2018
ER  -