Artery Research

Volume 6, Issue 4, December 2012, Pages 176 - 177

P2.46 THE “SYSTOLIC VOLUME BALANCE” METHOD FOR THE NON-INVASIVE ESTIMATION OF CARDIAC OUTPUT BASED ON PRESSURE WAVE ANALYSIS

Authors
O. Vardoulis, T.G. Papaioannou, N. Stergiopulos
École Polytechnique Fédérale de Lausanne, Lausanne, Switzerland
Available Online 17 November 2012.
DOI
10.1016/j.artres.2012.09.126How to use a DOI?
Open Access
This is an open access article distributed under the CC BY-NC license.

Cardiac output (CO) monitoring is essential for the optimal management of critically ill patients. Several methods have been proposed for CO estimation based on pressure waveform analysis. Most of them depend on invasive blood pressure recording and calibrations, while they suffer from decreased accuracy under specific conditions. A new Systolic Volume Balance (SVB) method was derived from a volume balance approach on the conservation of mass ejected into and flowed out of the arterial system during systole. The formula was validated by a one-dimensional model of the systemic arterial tree. Comparisons of CO estimates between the proposed and previous methods were performed in terms of agreement and accuracy by using the “real” CO values of the model as a reference. 507 different hemodynamic cases were simulated by altering cardiac period (T), arterial compliance (C) and resistance. CO could be accurately estimated by the SVB method: CO=C·PPao/(T-Psm·Ts/Pm) where PPao aortic pulse pressure, Ts systolic duration, Psm mean systolic pressure and Pm mean pressure. SVB applied on aortic pressure waves did not require calibration or empirical correction for CO estimation. An empirical coefficient (k) was necessary for brachial pressure wave analysis. The difference of SVB-derived from model CO, (for brachial waves), was 0.042 L/min with 0.341 L/min SD of difference. The limits of agreement were −0.7–0.6 L/min indicating high precision. The intraclass correlation coefficient and the root mean square error between estimated and “real” CO were 0.861 and 0.041 L/min, respectively, indicating very good accuracy.

Journal
Artery Research
Volume-Issue
6 - 4
Pages
176 - 177
Publication Date
2012/11/17
ISSN (Online)
1876-4401
ISSN (Print)
1872-9312
DOI
10.1016/j.artres.2012.09.126How to use a DOI?
Open Access
This is an open access article distributed under the CC BY-NC license.

Cite this article

TY  - JOUR
AU  - O. Vardoulis
AU  - T.G. Papaioannou
AU  - N. Stergiopulos
PY  - 2012
DA  - 2012/11/17
TI  - P2.46 THE “SYSTOLIC VOLUME BALANCE” METHOD FOR THE NON-INVASIVE ESTIMATION OF CARDIAC OUTPUT BASED ON PRESSURE WAVE ANALYSIS
JO  - Artery Research
SP  - 176
EP  - 177
VL  - 6
IS  - 4
SN  - 1876-4401
UR  - https://doi.org/10.1016/j.artres.2012.09.126
DO  - 10.1016/j.artres.2012.09.126
ID  - Vardoulis2012
ER  -