P2.33 PERIPHERAL VERSUS CENTRAL PULSE PRESSURE VALUES IN CALCULATIONS OF CAROTID DISTENSIBILITY AND COMPLIANCE
- DOI
- 10.1016/j.artres.2012.09.113How to use a DOI?
- Open Access
- This is an open access article distributed under the CC BY-NC license.
The aim of our study was to compare carotid compliance and distensibility calculations derived from central aortic pressure and peripheral brachial blood pressure measurements.
For this study 232 healthy, lifelong non-smoking, normotensive subjects (111 male & 121 female) were recruited (age 40±11 years, BMI 25.7±4.1 kg.m2). Augmentation index (AIx), central aortic pressure (Sphygmacor, Skidmore Medical, UK), pulse wave velocity (PWV; Vicorder, Skidmore Medical, UK) and brachial blood pressure (Dynamap Pro, GE, USA), were measured using applanation tonometry. Stroke changes in common carotid diameter and intima-media thickness (CIMT) were measured from ultrasound (Philips HDX7E, Philips, UK) images using semi-automated software1 (QLAB, Philips, UK). Carotid compliance and distensibility were subsequently calculated using brachial and aortic pulse pressure values.
Mean AIx, PWV and CIMT was 16.45±14.79 %, 7.04±1.22 m.s−1 and 0.52±0.07 mm respectively. Carotid distensibility & compliance values calculated using brachial blood pressure (35.08±22.25 kPa.10−3 & 11.23±7.95 m2.kPa.10−7) were significantly (p<0.001) lower compared to aortic derived measurements (48.63±34.81 kPa.10−3 & 15.68±13.09 m2.kPa.10−7). Spearman’s analysis showed that aortic derived calculations of compliance & distensibility were more strongly correlated with indices of arterial stiffness compared to brachial derived calculations (Table 1).
Brachial | Aortic | |||
---|---|---|---|---|
Distensibility | Compliance | Distensibility | Compliance | |
r | r | r | r | |
PWV | −0.0308 | −0.0367 | −0.3028** | −0.2674** |
AIx | 0.0843 | −0.0452 | −0.4298*** | −0.5250*** |
CIMT | −0.0598 | 0.0741 | −0.2327* | −0.1430 |
p<0.05,
p<0.01,
p<0.001.
Spearman’s correlation analysis between brachial/aortic pulse pressure derived distensibility/compliance measurements.
The results of the study reveal important considerations for blood pressure derived calculations of arterial stiffness.
Cite this article
TY - JOUR AU - O. Mac Ananey AU - V. Maher PY - 2012 DA - 2012/11/17 TI - P2.33 PERIPHERAL VERSUS CENTRAL PULSE PRESSURE VALUES IN CALCULATIONS OF CAROTID DISTENSIBILITY AND COMPLIANCE JO - Artery Research SP - 173 EP - 173 VL - 6 IS - 4 SN - 1876-4401 UR - https://doi.org/10.1016/j.artres.2012.09.113 DO - 10.1016/j.artres.2012.09.113 ID - Ananey2012 ER -