5.2 CUFF AND TONOMETER BASED DEVICE FOR ASSESSMENT OF CAROTID TO FEMORAL PULSE WAVE VELOCITY: VALIDATION ACCORDING TO ARTERY SOCIETY GUIDELINES

Authors
M. Butlin1, E. Bozec2, E. Millet-Amaury2, G. Pucci3, F. Battista3, A. Qasem1, G. Schillaci3, P. Boutouyrie2, A. Avolio1
1Macquarie University, Sydney, Australia
2INSERM U970, University Paris Descartes, Paris, France
3University of Perugia, Perugia, Italy
Available Online 17 November 2012.
DOI
10.1016/j.artres.2012.09.032How to use a DOI?
Open Access
This is an open access article distributed under the CC BY-NC license.

Background: There is increasing interest in cuff-based devices for assessment of arterial pulse wave velocity (PWV). A recently developed device utilises a thigh cuff and carotid applanation tonometry for assessment of carotid to femoral PWV (cPWV; SphygmoCor XCEL, AtCor Medical; test device). Our aim was to validate the device against ECG gated tonometric measurement of PWV (tPWV) (SphygmoCor CvMS; control device) according to Artery Society Guidelines [1].

Methods: We recruited 94 subjects (48 female, 22–83 years, mean age 45.6 ± 19.4) in 3 centres (Australia, France, Italy). The thigh cuff was inflated automatically to sub-diastolic pressure and the cuff waveform was recorded simultaneously with the tonometric carotid waveform. Control and test devices were used in random order. PWV was determined from wave foot-to-foot delay and distance from suprasternal notch to femoral site or top of cuff, minus distance from suprasternal notch to carotid site. The average was computed of triplicate measurements by two operators.

Results: A high correlation was found between devices (R2=0.90; Figure) with a mean difference of −0.02 ± 0.61 (SD) m/s. Mean difference and standard deviation (SD) between cPWV and tPWV was well within the “excellent” category acceptance criteria of the Artery Society guidelines (<0.5 m/sec and <0.80 m/sec, respectively).

Conclusion: The femoral cuff technique gives comparable PWV values to those acquired with the accepted standard ECG gated carotid/femoral tonometry PWV measurement technique.

Journal
Artery Research
Volume-Issue
6 - 4
Pages
149 - 149
Publication Date
2012/11/17
ISSN (Online)
1876-4401
ISSN (Print)
1872-9312
DOI
10.1016/j.artres.2012.09.032How to use a DOI?
Open Access
This is an open access article distributed under the CC BY-NC license.

Cite this article

TY  - JOUR
AU  - M. Butlin
AU  - E. Bozec
AU  - E. Millet-Amaury
AU  - G. Pucci
AU  - F. Battista
AU  - A. Qasem
AU  - G. Schillaci
AU  - P. Boutouyrie
AU  - A. Avolio
PY  - 2012
DA  - 2012/11/17
TI  - 5.2 CUFF AND TONOMETER BASED DEVICE FOR ASSESSMENT OF CAROTID TO FEMORAL PULSE WAVE VELOCITY: VALIDATION ACCORDING TO ARTERY SOCIETY GUIDELINES
JO  - Artery Research
SP  - 149
EP  - 149
VL  - 6
IS  - 4
SN  - 1876-4401
UR  - https://doi.org/10.1016/j.artres.2012.09.032
DO  - 10.1016/j.artres.2012.09.032
ID  - Butlin2012
ER  -