Aortic pulse wave velocity (PWV), wave reflection, measured as central augmentation index (AIx) and central (aortic) blood pressure (cSBP) are independent predictors for total and cardiovascular morbidity and mortality. The «BPLAB VASOTENS» is a new cuff-based, operator-independent device which obtains brachial BP waveforms derives (and saved in memory during 24-h) cSBP, AIx and PWV using brachial-to-aortic transfer function.

Aim: Compare «BPLAB VASOTENS» to standard techniques for measuring cSBP, AIx and PWV (SphygmoCor) in normotensive and hypertensive subjects.

Methods: 75 subjects (53 ± 12 years, 42% males) without cardiovascular

diseases and with arterial hypertension were studied after 10 minutes of supine rest. Brachial pressure waveforms calibrated to brachial systolic and diastolic pressure were recorded using the «BPLAB VASOTENS» and radial pressure waveforms calibrated to brachial mean and diastolic pressure were recorded using the SphygmoCor. The corresponding cSBP, AIx, PWV measurements were compared between devices (cSBPbp vs cSBPshyg, Aixbp vs AIxshyg, PWVbp vs PWVshyg).

Results: There was good agreement between cSBPbp (123 ± 19mmHg) and cSBPshyg

(120± 18mmHg; p<0.01, r=0.92, p<0.01). Moderate results were observed for AIx – 27± 6 vs 27 ± 11 (p=0.8, r= 0.64, p<0.01) and for PWV – 7.7± 0.6 m/s vs 7.9± 1.9 m/s, p=0.5, r= 0.45, p<0.01).

Conclusions: the values of cSBP, but not Aix and PWV provided by the «BPLAB VASOTENS» and SphygmoCor devices show good agreement. Further comparative data are required in a larger sample size, and with invasive BP measurements.

Journal
Artery Research
Volume-Issue
4 - 4
Pages
171 - 171
Publication Date
2010/12/02
ISSN (Online)
1876-4401
ISSN (Print)
1872-9312
DOI
10.1016/j.artres.2010.10.091How to use a DOI?
Open Access
This is an open access article distributed under the CC BY-NC license.

Cite this article

TY  - JOUR
AU  - A.N. Rogoza
AU  - N.M. Moiseeva
AU  - M.V. Sergeeva
PY  - 2010
DA  - 2010/12/02
TI  - P8.09 A COMPARISON OF CENTRAL BLOOD PRESSURES, AUGMENTATION INDEX AND PWV ESTIMATED BY «BPLAB VASOTENS» AND SPHYGMOCOR
JO  - Artery Research
SP  - 171
EP  - 171
VL  - 4
IS  - 4
SN  - 1876-4401
UR  - https://doi.org/10.1016/j.artres.2010.10.091
DO  - 10.1016/j.artres.2010.10.091
ID  - Rogoza2010
ER  -