The matching of vascular supply to neuronal metabolic demand during cognitive engagement is known as neurovascular coupling (NVC). Excessive hemodynamic pulsatility may have a detrimental effect on neural function and affect NVC. Arterial stiffness is a prominent determinant of pulsatility in the brain.1, 2
Objectives: We explored changes in arterial stiffness and cerebrovascular hemodynamic pulsatility during cognitive engagement in healthy adults.
Methods: Twenty-seven adults (age 39 ± 3 yrs, BMI 24±1 kg/m2) underwent Doppler ultrasonography and applanation tonometry of the common carotid artery (CCA) to derive 1) CCA elastic modulus (Ep) and β-stiffness index; 2) CCA flow pulsatility index (PI); 3) CCA pulse pressure (PP), and 4) CCA augmentation index (AIx). Transcranial Doppler was used to assess cerebral PI at the middle cerebral artery (MCA). All measures were made simultaneously at rest and during a 4-minute Stroop task.
Results: CCA PI was reduced (p<0.05) while MCA PI was unchanged (p>0.05) during Stroop. Brachial PP increased during Stroop (p<0.05) while CCA PP was unchanged (p>0.05). Similarly, CCA Ep (p>0.05) and β-stiffness (p>0.05) were unchanged. CCA AIx increased (p<0.05).
Conclusion: Carotid pressure pulsatility and cerebral flow pulsatility is unaltered while carotid flow pulsatility is reduced during cognitive engagement. Carotid stiffness does not change suggesting that factors other than the elastic properties of the vessel moderate cerebrovascular pulsatility during cognitive engagement.
Variable | Baseline | Stroop | P–value |
---|---|---|---|
Brachial pulse pressure, mmHg | 43 ± 1 | 46 ± 1 | 0.002 |
Carotid pulse pressure, mmHg | 36 ± 1 | 35 ± 1 | 0.324 |
Carotid β-stiffness, aU | 4.4 ± 0.4 | 4.2 ± 0.3 | 0.224 |
Carotid Ep, kPa | 54.5 ± 5.5 | 53.8 ± 4.9 | 0.670 |
Carotid pressure AIx, % | 1 ± 4 | 13 ± 4 | 0.001 |
Carotid distension AIx, % | 4 ± 2 | 8 ± 2 | 0.001 |
Carotid mean diameter, mm | 5.62 ± 0.13 | 5.74 ± 0.13 | 0.010 |
Carotid pulsatility index | 1.75 ± 0.06 | 1.57 ± 0.06 | 0.016 |
Cerebral pulsatility index | 0.75 ± 0.02 | 0.75 ± 0.01 | 0.841 |
Hemodynamic and vascular parameters at rest and during Stroop task.
References
Cite this article
TY - JOUR AU - Kevin S. Heffernan AU - Nicole L. Spartano AU - Jacqueline A. Augustine AU - Wesley K. Lefferts AU - William E. Hughes AU - Gary F. Mitchell AU - Randall S. Jorgensen AU - Brooks B. Gump PY - 2014 DA - 2014/11/04 TI - PO-05 BUFFERING OF CAROTID ARTERY PRESSURE AND FLOW PULSATILITY DURING COGNITIVE ENGAGEMENT IN HEALTHY ADULTS JO - Artery Research SP - 167 EP - 168 VL - 8 IS - 4 SN - 1876-4401 UR - https://doi.org/10.1016/j.artres.2014.09.011 DO - 10.1016/j.artres.2014.09.011 ID - Heffernan2014 ER -