P11.7 THE DECAY OF AORTIC BLOOD PRESSURE DURING DIASTOLE: INFLUENCE OF AN ASYMPTOTIC PRESSURE LEVEL ON THE EXPONENTIAL FIT

Authors
S. Parragha, b, B. Hametnera, b, T. Weberc, B. Eberc, S. Wassertheurera
aAIT Austrian Institute of Technology, Health & Environment Department, Vienna, Austria
bVienna University of Technology, Department for Analysis and Scientific Computing, Vienna, Austria
cKlinikum Wels-Grieskirchen, Cardiology Department, Wels, Austria
Available Online 4 November 2014.
DOI
10.1016/j.artres.2014.09.225How to use a DOI?
Open Access
This is an open access article distributed under the CC BY-NC license.

Aortic blood pressure is decreasing approximately exponentially during diastole and the time constant of the decay is supposed to hold information about total arterial compliance and peripheral resistance. However, it is unclear if the pressure would drop to zero without further excitations from the heart or if it would reach an asymptotic pressure level Pinf. The aim of this work was to examine the fitting performance of an exponential decay with and without Pinf in invasive aortic pressure readings with prolonged diastoles caused by missing heartbeats.

A total number of 35 pressure signals (5F Millar SPC-454D catheters) from 5 different subjects were examined. For the fitting procedure, the squared error between measured data and analytical function was minimized with Pinf ranging from 0 to 100% (5% steps) of the diastolic blood pressure DBP. The data was fitted over the duration of both, the regular and the prolonged diastole.

The irregular heartbeats were on average 1.7 (0.3 SD) times longer than the preceding beats. In all settings, mean root mean squared error RMSE between measured and calculated pressure drop was lowest for Pinf=0.7*DBP. For Pinf=0, the deviation was more than two times higher than for Pinf=0.7*DBP, regardless of the chosen part for fitting (mean RMSE: 1.8 (0.6 SD) and 5.2 (2.6 SD) with and without Pinf respectively when fitted to the first part).

The results indicate that an asymptotic pressure level exists, which is, at least for the observed timescales, maintained by the vascular system even without ejection from the heart.

Journal
Artery Research
Volume-Issue
8 - 4
Pages
162 - 162
Publication Date
2014/11/04
ISSN (Online)
1876-4401
ISSN (Print)
1872-9312
DOI
10.1016/j.artres.2014.09.225How to use a DOI?
Open Access
This is an open access article distributed under the CC BY-NC license.

Cite this article

TY  - JOUR
AU  - S. Parragh
AU  - B. Hametner
AU  - T. Weber
AU  - B. Eber
AU  - S. Wassertheurer
PY  - 2014
DA  - 2014/11/04
TI  - P11.7 THE DECAY OF AORTIC BLOOD PRESSURE DURING DIASTOLE: INFLUENCE OF AN ASYMPTOTIC PRESSURE LEVEL ON THE EXPONENTIAL FIT
JO  - Artery Research
SP  - 162
EP  - 162
VL  - 8
IS  - 4
SN  - 1876-4401
UR  - https://doi.org/10.1016/j.artres.2014.09.225
DO  - 10.1016/j.artres.2014.09.225
ID  - Parragh2014
ER  -