Artery Research

Volume 5, Issue 4, December 2011, Pages 202 - 202

12.06 COMPARISON OF SIMULTANEOUS INVASIVE CENTRAL ARTERIAL PRESSURE MEASUREMENTS WITH NON-INVASIVE ARTERIAL PRESSURE ESTIMATES BY SUPRASYSTOLIC OSCILLOMETRY USING PULSECOR R6.5

Authors
A. Lin1, A. Lowe2, 3, K. Sidhu1, W. Harrison1, P. Ruygrok1, R. Stewart1
1Green Lane Cardiovascular Service, Auckland City Hospital, Auckland, New Zealand
2Institute of Biomedical Technologies, AUT University, Auckland, New Zealand
3Pulsecor Limited, Auckland, New Zealand
Available Online 29 November 2011.
DOI
10.1016/j.artres.2011.10.191How to use a DOI?
Open Access
This is an open access article distributed under the CC BY-NC license.

Background: Many devices estimate central aortic blood pressure (BP) from non-invasive measurements. Most need calibration using separately measured BP, which introduces unquantified inaccuracies. The Pulsecor R6.5 device estimates central BP using a suprasystolic brachial cuff and built-in oscillometric BP unit in approximately 60 seconds. We compared central BP estimated using the Pulsecor device and those obtained by catheter during coronary angiography.

Methods: 94 central pressure waveforms were recorded by catheter in 37 subjects (61±12yrs) undergoing diagnostic coronary angiography. Pulsecor central pressures were compared using Bland-Altman analysis with ensemble-averaged catheter pressures obtained simultaneously over the period of the Pulsecor measurement.

Results: Cohort mean central BPs estimated by Pulsecor and invasively were very similar. The spread of differences was larger for systolic than diastolic and mean pressures, although all were within Association for the Advancement of Medical Instrumentation (AAMI) standards.

Conclusions: Pulsecor R6.5 accurately estimates central aortic BPs calibrated using built-in oscillometric BP measurement.

Central BP Catheter Pulsecor Difference P-value Pearson’s r
Systolic 122.3±23.6 122.3±22.3 0.0±7.7 1.00 0.95
Diastolic 68.7±8.6 68.8±6.00 0.1±5.1 0.9372 0.81
MAP 91.3±11.5 91.3±10.0 0.0±4.8 0.9785 0.91

Data reported as mean±sd, mmHg

Journal
Artery Research
Volume-Issue
5 - 4
Pages
202 - 202
Publication Date
2011/11/29
ISSN (Online)
1876-4401
ISSN (Print)
1872-9312
DOI
10.1016/j.artres.2011.10.191How to use a DOI?
Open Access
This is an open access article distributed under the CC BY-NC license.

Cite this article

TY  - JOUR
AU  - A. Lin
AU  - A. Lowe
AU  - K. Sidhu
AU  - W. Harrison
AU  - P. Ruygrok
AU  - R. Stewart
PY  - 2011
DA  - 2011/11/29
TI  - 12.06 COMPARISON OF SIMULTANEOUS INVASIVE CENTRAL ARTERIAL PRESSURE MEASUREMENTS WITH NON-INVASIVE ARTERIAL PRESSURE ESTIMATES BY SUPRASYSTOLIC OSCILLOMETRY USING PULSECOR R6.5
JO  - Artery Research
SP  - 202
EP  - 202
VL  - 5
IS  - 4
SN  - 1876-4401
UR  - https://doi.org/10.1016/j.artres.2011.10.191
DO  - 10.1016/j.artres.2011.10.191
ID  - Lin2011
ER  -