Volume 5, Issue 4, December 2011, Pages 152 - 153

P2.01 RELATIONSHIP BETWEEN MEDIA TO LUMEN RATIO OF SUBCUTANEOUS SMALL ARTERIES AND WALL TO LUMEN RATIO OF RETINAL ARTERIOLES EVALUATED NON INVASIVELY BY SCANNING LASER DOPPLER FLOWMETRY

Authors
D. Rizzoni1, E. Porteri1, C. De Ciuceis1, E. La Boria1, S. Duse3, F. Semeraro3, C. Costagliola4, A. Sebastiani5, P. Danzi3, G.A.M. Tiberio2, S.M. Giulini2, C. Agabiti Rosei1, A. Sarkar1, D. Avanzi1, E. Agabiti Rosei1
1Clinica Medica, Department of Medical and Surgical Sciences, University of Brescia, Brescia, Italy
2Clinica Chirurgica, Department of Medical and Surgical Sciences, University of Brescia, Brescia, Italy
3Chair of Ophthalmology, University of Brescia, Brescia, Italy
4Chair of Ophthalmology, University of Molise, Campobasso, Italy
5Chair of Ophthalmology, University of Ferrara, Ferrara, Italy
Available Online 29 November 2011.
DOI
10.1016/j.artres.2011.10.022How to use a DOI?
Open Access
This is an open access article distributed under the CC BY-NC license.

Structural alterations of subcutaneous small resistance arteries, as indicated by an increased media to lumen (M/L) ratio, are frequently present in hypertensive and/or diabetic patients, and may represent the earliest alteration observed. In addition, M/L of small arteries evaluated by micromyography has a strong prognostic significance; however its extensive evaluation is limited by the invasivity of the assessment, since a biopsy of subcutaneous fat is needed. Non-invasive measurement of wall to lumen (W/L) of retinal arterioles using scanning laser doppler flowmetry (SLDF) has been recently introduced (Harazny J et al, Hypertension 2007; 50:623–629). However, this new technique was never compared with micromyographic measurement, considered the gold standard approach.

Methods and Results: We have investigated 37 subjects and patients. Twenty-three of them were hypertensives and 14 normotensives. Blood pressure values were 139/88±17/10 mmHg and 125/71±17/12 mm Hg, respectively (p<0.05). All patients underwent a biopsy of subcutaneous fat during an elective surgical intervention. Subcutaneous small resistance arteries were dissected and mounted on a wire myograph, and M/L was measured. In addition, an evaluation of W/L of retinal arterioles by SLDF was performed (Heidelberg Retina Flowmeter, Heidelberg Engineering). A close correlation was observed between M/L of subcutaneous small arteries and WL of retinal arterioles: r=0.77, p<0.001 (see Figure).

Conclusion: A non invasive and easily repeatable procedure (intraobserver and interobserver variation coefficient around 10%) such as an evaluation of the arterioles in the fundus oculi by SDLF may provide similar information regarding microvascular morphology compared in respect with an invasive, accurate and prognostically relevant micromyographic measurement of M/L.

Journal
Artery Research
Volume-Issue
5 - 4
Pages
152 - 153
Publication Date
2011/11/29
ISSN (Online)
1876-4401
ISSN (Print)
1872-9312
DOI
10.1016/j.artres.2011.10.022How to use a DOI?
Open Access
This is an open access article distributed under the CC BY-NC license.

Cite this article

TY  - JOUR
AU  - D. Rizzoni
AU  - E. Porteri
AU  - C. De Ciuceis
AU  - E. La Boria
AU  - S. Duse
AU  - F. Semeraro
AU  - C. Costagliola
AU  - A. Sebastiani
AU  - P. Danzi
AU  - G.A.M. Tiberio
AU  - S.M. Giulini
AU  - C. Agabiti Rosei
AU  - A. Sarkar
AU  - D. Avanzi
AU  - E. Agabiti Rosei
PY  - 2011
DA  - 2011/11/29
TI  - P2.01 RELATIONSHIP BETWEEN MEDIA TO LUMEN RATIO OF SUBCUTANEOUS SMALL ARTERIES AND WALL TO LUMEN RATIO OF RETINAL ARTERIOLES EVALUATED NON INVASIVELY BY SCANNING LASER DOPPLER FLOWMETRY
JO  - Artery Research
SP  - 152
EP  - 153
VL  - 5
IS  - 4
SN  - 1876-4401
UR  - https://doi.org/10.1016/j.artres.2011.10.022
DO  - 10.1016/j.artres.2011.10.022
ID  - Rizzoni2011
ER  -