Artery Research

Volume 3, Issue 4, December 2009, Pages 167 - 167

P9.01 NON - INVASIVE EVALUATION OF ATHEROSCLEROTIC PLAQUE COMPOSITION: COMPARISON BETWEEN THE REFERENCE ANALYZER AND A NEW GRAY SCALE MEDIAN COLOR-MAPPING SOFTWARE

Authors
P.J. Forcada, S.A. Gonzalez, D. Olano, E. Cavanagh, S. Obregon, C. Castelaro, C. Kotliar
Hospital Univeritario Austral, Prov.Buenos Aires, Argentina
Available Online 3 December 2009.
DOI
10.1016/j.artres.2009.10.121How to use a DOI?
Abstract

Introduction: The non-invasive analysis of plaque echolucency (ECL) with Adobe Photoshop® has proven to reduce the subjectivity of ultrasonic evaluation of atherosclerosis. However, ECL provides information concerning only one of the aspects that contribute to vulnerability (plaque echodensity). Hemodyn 4m® is a grey scale median (GSM) plaque analyzer to asses distribution of areas with different tissue composition within atherosclerotic plaques, based in a color mapping process. AIM: To evaluate the correlation and concordance of a new GSM and color mapping plaque analyzer, Hemodyn 4m®, with the current reference method, Adobe Photoshop®.

Methods: Evaluation of fifty carotid atherosclerotic plaques (miointima thickness above 1.2mm) obtained with a 10 MHZ linear array transducer (Vivid Five®, G. E. Corp.) from 50 consecutive patients. Correlation analysis was done with Spearman test; concordance, intraobserver and interobserver analysis with Bland and Altmann method.

Results: Hemodyn 4m® show excellent correlation (GSM, r2: 0.84, p< 0.001) and concordance with Adobe Photoshop® (difference of Hemodyn 4m® compared to Adobe® Photoshop, - 1.9 units of the GSM average values, 2SD ±17.8; n=50), with low intraobserver (Difference Hemodyn 4 m®, 1 units of values of grey scale average median, SD±15.8; n=25) and interobserver variability (Difference with Hemodyn 4 m®, 0.4 units of values of GSM average, SD±16.8; n=25).

Conclusion: Adobe Photoshop® and Hemodyn 4m® are equivalent methods for GSM analysis of the ECL plaque evaluation. Hemodyn 4m® provides a more accurate visual characterization and location of the different tissue components of atherosclerotic plaques.

Open Access
This is an open access article distributed under the CC BY-NC license.

Journal
Artery Research
Volume-Issue
3 - 4
Pages
167 - 167
Publication Date
2009/12/03
ISSN (Online)
1876-4401
ISSN (Print)
1872-9312
DOI
10.1016/j.artres.2009.10.121How to use a DOI?
Open Access
This is an open access article distributed under the CC BY-NC license.

Cite this article

TY  - JOUR
AU  - P.J. Forcada
AU  - S.A. Gonzalez
AU  - D. Olano
AU  - E. Cavanagh
AU  - S. Obregon
AU  - C. Castelaro
AU  - C. Kotliar
PY  - 2009
DA  - 2009/12/03
TI  - P9.01 NON - INVASIVE EVALUATION OF ATHEROSCLEROTIC PLAQUE COMPOSITION: COMPARISON BETWEEN THE REFERENCE ANALYZER AND A NEW GRAY SCALE MEDIAN COLOR-MAPPING SOFTWARE
JO  - Artery Research
SP  - 167
EP  - 167
VL  - 3
IS  - 4
SN  - 1876-4401
UR  - https://doi.org/10.1016/j.artres.2009.10.121
DO  - 10.1016/j.artres.2009.10.121
ID  - Forcada2009
ER  -