Artery Research

Volume 3, Issue 4, December 2009, Pages 162 - 162

P1.07 MEASUREMENT OF CAROTID INTIMA-MEDIA THICKNESS IN HEALTHY PERSONS AND PATIENTS WITH TYPE 2 DIABETES - A REPRODUCIBILITY STUDY

Authors
L. Lundby Christensen1, T. Almdal1, A. Vaag1, B. Carstensen1, L. Tarnow1, N. Wiinberg2
1Steno Diabetes Center, Gentofte, Denmark
2Frederiksberg Hospital, Frederiksberg, Denmark
Available Online 3 December 2009.
DOI
10.1016/j.artres.2009.10.010How to use a DOI?
Abstract

Background: Carotid intima-media thickness (IMT) measured by B-mode ultrasound is a sensitive and non-invasive method for detection of subclinical cardiovascular disease (CVD) and is often used as primary outcome measure in clinical trials as a surrogate marker of CVD. The purpose of the present study was to quantify the repeatability of this method between and within sonographers and readers. Furthermore we studied the day-to-day variation.

Methods: We used B-mode ultrasound and a computerized software programme (MIA vascular tools) for analysis of Carotid IMT (far wall of the common carotid artery). Measurement of Carotid IMT was done for 30 healthy persons and 28 T2D patients by two different sonographers and two different readers on two separate days.

Results: Comparisons of Carotid IMT between readers assessing the same picture (reader variability) resulted in limits of agreement on the relative scale from 0.92 to 1.07, i.e. there is a 95% probability that the reading of a given picture by a second reader gives a thickness between 0.92 and 1.07 of the first reading. Comparing different sonographers resulted in limits of agreement from 0.83 to 1.22

We found no differences between healthy persons and patients with T2D.

Conclusion: Measurement of carotid IMT has the same accuracy in both healthy persons and patients with T2D. The major sources of variation are the differences between sonographers and the day-to-day variation whereas the following reading of the recording using computerized software shows very little variation.

Open Access
This is an open access article distributed under the CC BY-NC license.

Journal
Artery Research
Volume-Issue
3 - 4
Pages
162 - 162
Publication Date
2009/12/03
ISSN (Online)
1876-4401
ISSN (Print)
1872-9312
DOI
10.1016/j.artres.2009.10.010How to use a DOI?
Open Access
This is an open access article distributed under the CC BY-NC license.

Cite this article

TY  - JOUR
AU  - L. Lundby Christensen
AU  - T. Almdal
AU  - A. Vaag
AU  - B. Carstensen
AU  - L. Tarnow
AU  - N. Wiinberg
PY  - 2009
DA  - 2009/12/03
TI  - P1.07 MEASUREMENT OF CAROTID INTIMA-MEDIA THICKNESS IN HEALTHY PERSONS AND PATIENTS WITH TYPE 2 DIABETES - A REPRODUCIBILITY STUDY
JO  - Artery Research
SP  - 162
EP  - 162
VL  - 3
IS  - 4
SN  - 1876-4401
UR  - https://doi.org/10.1016/j.artres.2009.10.010
DO  - 10.1016/j.artres.2009.10.010
ID  - LundbyChristensen2009
ER  -