Abstract

Background: Despite the introduction of arterial stiffness measurements in the recommendation of the European Societies for Hypertension and Cardiology, pulse wave velocity (PWV) and augmentation index (Aix) are still not used routinely in clinical practice. Possibly, current techniques, although non-invasive, validated, and easy to use, are still impractical and not favoured by patients. This includes the ability to perform such measurements in the sitting position as is done for blood pressure. New devices allow measurements in the sitting position. The aim of this study was to evaluate the role of posture on PWV and Aix, and to assess whether arterial stiffness measurements can be reliably measured in the supine position.

Methods: Arterial stiffness parameters were measured in 15 healthy volunteers and 15 patients with cardiovascular disease using three different devices: Arteriograph® (Arteriomed) and Vascular Explorer® (Enverdis) determining PWV and Aix from oscillometrically recorded pulse waves from the brachial artery; and SphygmoCor® (Atcor Medical). Three measurements were performed in supine position followed by three measurements in the sitting position.

Results: Arterial stiffness parameters did not differ between supine and sitting position. The table shows the results of the measurements (mean±SD).

PWV m/s Supine Position Sitting Position p-value
Arteriograph 7.6±1.6 7.7±1.8 0.29
Vascular Explorer 8.2±0.9 8.5±1.5 0.37
SphygmoCor 7.3±1.5
Aix % Supine Position Sitting Position p-value
Arteriograph 18.4±16.0 19.2±16.4 0.35
Vascular Explorer 5.6±13.1 8.1±13.0 0.14
SphygmoCor 6.0±9.4 6.2±8.3 0.32

Conclusions: The close agreement between sitting and supine measurements suggests that both PWV and Aix can be reliably measured in the sitting position.

Open Access
This is an open access article distributed under the CC BY-NC license.

Download article (PDF)
View full text (HTML)

Journal
Artery Research
Volume-Issue
3 - 4
Pages
167 - 167
Publication Date
2009/12/03
ISSN (Online)
1876-4401
ISSN (Print)
1872-9312
DOI
10.1016/j.artres.2009.10.122How to use a DOI?
Open Access
This is an open access article distributed under the CC BY-NC license.

Cite this article

TY  - JOUR
AU  - J. Nuernberger
AU  - R. Michalski
AU  - A. Opazo Saez
AU  - A. Kribben
PY  - 2009
DA  - 2009/12/03
TI  - P9.02 EVALUATION OF PULSE WAVE VELOCITY AND AUGMENTATION INDEX IN SUPINE AND SITTING POSITION
JO  - Artery Research
SP  - 167
EP  - 167
VL  - 3
IS  - 4
SN  - 1876-4401
UR  - https://doi.org/10.1016/j.artres.2009.10.122
DO  - 10.1016/j.artres.2009.10.122
ID  - Nuernberger2009
ER  -