Artery Research

Volume 25, Issue 3-4, December 2019, Pages 139 - 144

Influence of Ultrasound Settings on Carotid Biomarker Assessment by B-mode Image Processing

Authors
Martina Francesconi1, 2, *, Vincenzo Gemignani1, Rachele Gherardini2, Nicole Di Lascio1, Francesco Faita1, Lorenzo Ghiadoni2, Rosa Maria Bruno3, 4, #, Elisabetta Bianchini1, #
1Institute of Clinical Physiology, Italian National Research Council, Pisa, Italy
2Department of Clinical and Experimental Medicine, University of Pisa, Pisa, Italy
3Département de Pharmacologie, Université de Paris, Paris, France
4INSERM, U970, Paris Cardiovascular Research Center – PARCC, Paris, France
#

These two authors contributed equally to this work.

*Corresponding author. Email: martinafrancesconi@ifc.cnr.it
Corresponding Author
Martina Francesconi
Received 22 November 2019, Accepted 26 November 2019, Available Online 5 December 2019.
DOI
10.2991/artres.k.191127.001How to use a DOI?
Keywords
Carotid biomarker; Carotid IMT; Carotid distension; Ultrasound settings; Semi-automatic software
Abstract

Introduction: This study aims to investigate how image settings affect carotid Intima-Media-Thickness (IMT) and diameter estimation performed with Carotid Studio (Quipu-Srl).

Methods: Fourteen healthy volunteers (24.4 ± 4.4 years; eight men) were recruited. Longitudinal scans 3-cm-deep of common-carotid-arteries with the same region-of-interest were obtained by expert operator, starting from a “default-setup” (central Time Gain Compensation-TGC; gain: 50 dB; no persistence filter) and adjusting one parameter at a time (oblique TGC; gain: 10 dB increments from 30 to 70 dB; persistence filter). The acquisition was performed twice, and repeatability was expressed for each setup as Coefficient of Variation (CV). Significant changes (p ≤ 0.05) compared with the “default-setup” were analysed by Wilcoxon signed-rank-test.

Results: Sixty and 70 dB gain resulted in overestimating IMT (from 0.460 ± 0.001 to 0.506 ± 0.030 mm and 0.538 ± 0.011 mm, p = 0.002 and 0.023 respectively vs. default-50 dB), underestimating the mean diameter (from 6.044 ± 0.040 mm to 5.763 ± 0.004 mm, p = 0.008 and to 5.698 ± 0.225 mm, p = 0.002), and for 70 dB, increasing IMT CV from 2.14 ± 1.92% to 6.85 ± 5.23% (p = 0.01) and diameter CV from 1.79 ± 1.22% to 4.77 ± 4.71% (p = 0.05). Distension CV increased from 5.71 ± 4.31% to 10.84 ± 5.91% (p = 0.041) and to 12.59 ± 7.97% (p = 0.021) for 60 and 70 dB respectively. Persistence and TGC did not affect repeatability, whereas diameter (5.955 ± 0.033 mm, p = 0.005) and distension (from 0.816 ± 0.019 mm to 0.655 ± 0.018 mm, p = 0.002) values were underestimated when persistence filter was active.

Discussion: Precision and reproducibility of carotid parameters, automatically assessed by Carotid Studio, are affected by high gain levels, due to image grey-level saturation. Persistence filter activation leads to underestimate diameter and distension, possibly due to mathematical operator behaviour and image temporal filtering. Since ultrasound setup significantly affects carotid parameter assessment, it should be reported and replicated in follow-up scans.

HIGHLIGHTS

  • We investigated how ultrasound imaging setup may affect carotid parameters.

  • Carotid parameters’ reproducibility was lower with high-gain values.

  • Persistence filter leads to underestimation of diameter and distension.

  • The scan projection seems to influence carotid parameter estimation.

  • Image depth should be kept at the lowest attainable value for best repeatability.

Copyright
© 2019 Association for Research into Arterial Structure and Physiology. Publishing services by Atlantis Press International B.V.
Open Access
This is an open access article distributed under the CC BY-NC 4.0 license (http://creativecommons.org/licenses/by-nc/4.0/).

Download article (PDF)
View full text (HTML)

Journal
Artery Research
Volume-Issue
25 - 3-4
Pages
139 - 144
Publication Date
2019/12/05
ISSN (Online)
1876-4401
ISSN (Print)
1872-9312
DOI
10.2991/artres.k.191127.001How to use a DOI?
Copyright
© 2019 Association for Research into Arterial Structure and Physiology. Publishing services by Atlantis Press International B.V.
Open Access
This is an open access article distributed under the CC BY-NC 4.0 license (http://creativecommons.org/licenses/by-nc/4.0/).

Cite this article

TY  - JOUR
AU  - Martina Francesconi
AU  - Vincenzo Gemignani
AU  - Rachele Gherardini
AU  - Nicole Di Lascio
AU  - Francesco Faita
AU  - Lorenzo Ghiadoni
AU  - Rosa Maria Bruno
AU  - Elisabetta Bianchini
PY  - 2019
DA  - 2019/12/05
TI  - Influence of Ultrasound Settings on Carotid Biomarker Assessment by B-mode Image Processing
JO  - Artery Research
SP  - 139
EP  - 144
VL  - 25
IS  - 3-4
SN  - 1876-4401
UR  - https://doi.org/10.2991/artres.k.191127.001
DO  - 10.2991/artres.k.191127.001
ID  - Francesconi2019
ER  -